List of parameters
Parameter Description
Unit of
measure
Default Range Notes
P00 Hydraulic con guration -- 2 2..5
2 = combi boiler
3 = not applicable
4 = not applicable
5 = not applicable
P01 Gas type --
0 NG
1 LPG
0..1
0 = methane (G20)
1 = GPL (G31)
P02 System type -- 0 0..1
0 = HT (high temperature)
1 = not used
P03 Ignition ramp time Min 1 0..30 0 = disabled
P04 Delay to prevent water hammer Sec 2 0..20 0 = disabled
P05 CH OFF time Min 3 0..10 0 = disabled
P06 Post-circulation pump in CH Min 3 0..10 0 = disabled
P07 Post-circulation pump in DHW Min 1 0..10 0 = disabled
P08 Minimum power DHW % 0 0..100
P09 Minimum power CH % 0 0..100
P10 Maximum power CH % 100 0..100
P11 Maximum power DHW % 100 0..100
P12 Not applicable -- 1 0..1 0 = disabled
P13 Outdoor sensor coef cient -- 0 0..30 0 = disabled
P14 MIN setpoint CH °C
25
20..40
if P02 = 1 not used
30 if P02 = 0 (HT)
P15 MAX setpoint CH °C
45 40..55 if P02 = 1 not used
80 40..88 if P02 = 0 (HT)
P16 MAX setpoint DHW °C
60 45..75 if P00 = 2
-- --
if P00
2
P17 Maximum circulator speed % 100 60..100 not used
P18 Starting delay CH Sec 0 0..199
P19 Enable gas valve trim -- 0 0..1 0 = disabled
P20 Not applicable °C 5 3..9 Not applicable to this model
P21 Not applicable -- 0 0..1 0 = disabled
P22 (if P21=1) Not applicable
rpm x10
140
140..180
if P01= 0 (G20)
1000
140
if P01= 1 (G31)
P23 (if P21=1) Not applicable rpm x10
100
100..140
if P01 = 0 (G20)
100
if P01= 1 (G31)
P24 (if P21=1) Not applicable rpm x10
110
110..140
if P01= 0 (G20)
115
if P01 = 1 (G31)
b
The boiler parameters must only be set or modi ed by professionally quali ed personnel. The manufacturer shall not be liable for malfunctions or damage caused by improper
con guration of the appliance.
mode.
By pressing the RESET button for 10 seconds, you can exit the installer mode.
If no key is pressed within 15 minutes, parameter mode is automatically exited.
4.12 Info menu (In)
b
Access to the menu is not allowed with the boiler in the OF state.
Access the Info menu as follows:
- Press the RESET button for 10 seconds to enter con guration mode. "tS" begins to ash
on the display.
- Press the CH+ or CH- buttons to navigate the menu and select the Info menu (In).
+
-
- Press MODE to con rm, the display shows the rst Info parameter.
- Press the CH+ or CH- buttons to select the parameter number.
- The parameter value is shown alternately with the parameter number (2 seconds each).
Info list
1 DHW sensor temperature °C 0..125
2 CH sensor temperature °C 0..125