6 COMMISSIONING
- Position the system’s master switch to the “on” position.
- Open the gas tap to allow fuel to ow.
6.1 Ignition
To start up the boiler, proceed as follows:
- power the boiler
- open the gas tap to allow fuel ow
- adjust the room thermostat to the required temperature (~20°C).
After ignition, the boiler is in standby mode until the burner ignites following a demand for
heat. Burner ignition is indicated by the
symbol on the display.
The level bar indicates whether the boiler is operating with a modulation range of 0 to 50%
=
or 51% to 100% = .
The boiler continues to function until the temperatures set on the boiler are reached, or the
heat request terminates; it will then go back to standby.
In the event of shutdown due to a fault, the digital display will show the relevant error code
and, in the case of a non-volatile error, the ame lockout symbol
.
6.2 Operating modes
- Repeatedly pressing the MODE button displays in sequence the possible operating
modes:
- OFF WINTER SUMMER CH ONLY (DO NOT SET THIS CONFIGURATION)
OFF
MODE
M
OD
E
WINTER
MODE
M
OD
E
SUMMER
Winter: press MODE until you see . The boiler is ready to supply both DHW and
CH. The digital display indicates the CH water temperature.
Summer: press
MODE
until you see . The boiler supplies only domestic hot water. The
digital display normally indicates the outlet temperature, and in the event of DHW demand
the temperature of the DHW.
OFF: to switch off the boiler press the MODE button until you see OF on the display. For
further details see "4.6 Temporary switch-off".
- Adjusting the CH water temperature
To adjust the CH water temperature, press the CH+ button to increase the value, CH- to
decrease it, within the CH setpoint limits (30°C - 80°C).
+
-
During a CH demand the symbol ashes on the display until the demand is met.
- Adjusting the domestic hot water temperature
To adjust the DHW temperature, press the DHW+ button to increase the value, DHW- to
decrease it, within the DHW setpoint limits (35°C - 60°C).
+
-
During a DHW demand the symbol ashes on the display, alternating with the letters
SA, until the demand is met.