17
ENGLISH
Serial number plate
Qnw Domestic hot water function
Heating function
Qn Nominal heat delivery
Pn Nominal heat output
Qm Reduced heat delivery
IP Degree of Protection
Pmw Maximum DHW pressure
Pms Maximum heating pressure
T Temperature
D Specifi c fl ow rate
NOx NOx class
ADDED DEVICES CLASS BONUS
OUTDOOR TEMPERATURE SENSOR II 2%
OT CONTROL PANEL (*) V 3%
OUTDOOR TEMPERATURE SENSOR + OT CONTROL PANEL (*) VI 4%
NOTE
With reference to the Delegated Regulation (EU) No. 811/2013, the information in the table can be used for completing the product data sheet and the labelling for room heating appliances, for mixed
heating appliances, for all those appliances for enclosed space heating, for temperature control devices and solar devices:
(*) Set as a room regulator
Parameter Symbol CIAO AT
25C
Unit
Seasonal space heating energy efficiency class - B -
Water heating energy efficiency class -A-
Rated heat output Pnominal 24 kW
Seasonal space heating energy efficiency ηs87 %
Useful heat output
At rated heat output and high-temperature regime (*) P4 24,0 kW
At 30% of rated heat output and low-temperature regime (**) P1 7,6 kW
Useful efficiency
At rated heat output and high-temperature regime (*) η4 86,1 %
At 30% of rated heat output and low-temperature regime (**) η1 91,6 %
Auxiliary electricity consumption
At full load elmax 69,0 W
At part load elmin 37,0 W
In Stand-by mode PSB 3,0 W
Other parameters
Stand-by heat loss Pstby 49,0 W
Pilot flame energy consumption Pign - W
Annual energy consumption QHE 51 GJ
Sound power level, indoors LWA 52 dB
Emissions of nitrogen oxides NOx 35 mg/kWh
For combination heaters
Declared load profile XL
Water heating energy efficiency ηwh 82 %
Daily electricity consumption Qelec 0,135 kWh
Daily fuel consumption Qfuel 24,092 kWh
Annual electricity consumption AEC 30 kWh
Annual fuel consumption AFC 18 GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
Qn (Hi) =
Serial N.
230 V ~ 50 Hz W
NOx:
Pms = bar T= °C
Pn =
Via Risorgimento 23/A - 23900 Lecco (LC) Italy
IP
Pmw = bar T= °C
D: l/min
50-30 °C
80-60
°C
Qn
Qn
Qm
kW
kW
kW
kW
kW
kW
kW
CIAO AT 25C
80-60
°C
Qnw