- 20 -
V. 2.0
11. Problems and Solutions
Problem Causes Solution
The pump does not
achieve the desired
pressure
One or more valves have worn
housings
Suction hose with air pockets
or irregular bends
Worn nozzles or of incorrect
diameter (See table)
Filter blocked
Check valves
Check hose
Check nozzles
Clean filter, replace
cartridge
Oscillating pressure
gauge
The pump is taking in air or
presence of air in circuit, air
not completely evacuated from
pump;
One or more valves blocked
Make the pump turn with
delivery open to evacuate
air;
Clean or replace the valves
The water pumped out is
irregular, the pressure
gauge oscillates
The air chamber is under-inflated
Inflate the air chamber (see
table)
Flow capacity
decreasing, pump noisy.
Oil level is low
Re-fill oil up to half way up
tank with pump running
Oil coming out of
discharge
1 or more membranes broken
STOP THE PUMP
IMMEDIATELY!
Empty the pump of oil, remove
heads and replace the
damaged membranes. Re-fill
oil.
Oil changes colour,
becomes white
1 or more membranes broken
STOP THE PUMP
IMMEDIATELY!
Empty the pump of oil, remove
the heads and replace the
damaged membranes.
Re-fill with oil.