Digital Frequency-Tacho-Linespeed Meter
IBEST ELECTRICAL CO.,LTD
DPF SERIES
Measuring object: frequency and tacho or linespeed.
Red LED display, 14.2 mm high.
Soft buttons, easily operate.
Measuring range: max.9999(4 digit), 999999(6 digit).
Measuring frequency is selectable: 1KHz / 10KHz.
Decimal point and modulus can be set freely;
Refresh time and zero-return time can be set within 0~9s.
Power fail holing function, up to 10 years.
With or without analog output:0~20mA or 4~20mA
Relay and transistor output at the same time ( to drive solid state relay)
1.FEATURES
2.ORDERING CODE
3.PANEL INSTRUCTIONS
Dear clients, thanks for choosing IBEST DPF Series frequency-tacho-linespeed meter! Before installing and operating the products, please read
this instruction manual carefully. For any questions, please contact our sales people immediately.
!
!
SAFETY CAUTIONS:
● Make sure the power is at “OFF” status before connecting the wires to avoid electric shock and strictly follow the connection diagram
given out by the factory.
● Make sure the power OFF when cleaning the product.
● Working beyond the stated power supply (90-250V AC) is prohibited so as to avoid damage to the product or cause fire.
● Make sure the OUTPUT RELAY is used at the rated load and electrical life, if the contact of the output reply works against the electrical
life, it may melt or burned or even cause fire.
● Install power switches and circuit breaker for power safety.
STOCK AND MAINTAINENCE NOTICE:
● Try to avoid interfere headstream, input signals cable should not be too long, better to use twisted-pair shielded cable, shielded layer
connected with singals low end.
● Prevent from violent vibration, shock and incursion of heavy dust.
● Stock long terms at 0~50 ć , under 35~85ˁRH environment.
● When instrument power supply has noises, paticularly when inductive voltage caused by relay or contact devices switch ONand OFF
result in serious interference, must configure filter or rheostat or noises absorber.
PREREAD INSTRUCTIONS
a. 48×96mm panel instructions
OUT2
OUTG
OUT1
SET2
SET1
RSTRSTRST RSTRST
MODE
RSTRST RSTRST
Output indicate lamp
Current set value
indicate lamp
Set value modify key
Operation mode key, press 3s to enter
into operation mode menu
Digit shift key
Value increase key or
parameters convert key
Display measuring value
Display the set value
DPF
1
A
A
B
Digital frequency/tacho/
linespeed meter
A
A: analog output 4~20mA
Frequency/Tacho meter
Dimension: 48×48 mm
Dimension: 72×72 mm
4 digit display
6 digit display
Dimension: 48×96 mm
Linespeed meter
Blank: No analog output
A
R
R
1: 1 alarm output
2: 2 alarm output
Alarm output: Blank: no alarm output
Output: relay and transistor
1
4
6
4
4
8
4
7
2
Question and Answer IconNeed help?

Do you have a question about the Best DPF Series and is the answer not in the manual?

Summary

Pre-read Instructions

Safety Cautions

General safety precautions for installation and operation to prevent electric shock and product damage.

Stock and Maintenance Notice

Guidelines for handling, storage, and maintenance to prevent interference and damage.

Ordering Code

Panel Instructions

48 x96 mm Panel Instructions

Details the layout and operation of the 48x96mm panel with button descriptions.

48 x48 mm; 72 x72 mm Panel Instructions

Explains the layout and operation of the 48x48mm and 72x72mm panels.

Technical Specifications

Electrical Connection Drawing

Operation Instructions

1 Set Stage Operation Instructions

Step-by-step guide for setting values and navigating the operation menu.

2 Stage Counter Operation Instructions

Instructions for setting and modifying high/low limit values for two-stage counters.

Comparator Output

Details on how high and low limit outputs function based on measured values.

Update Time

Explanation of the 'UPDA' parameter for setting display refresh and comparator output timing.

Operation Parameters Menu for Frequency and Tacho Meter

Guide to setting parameters like input mode, division modulus, and decimal point.

Operation Parameters Menu for Linespeed Meter

Guide to setting parameters like multiplication modulus and division modulus for linespeed.

Analog Output Adjustment

Procedure for setting analog output high and low limit values for 4-20mA or 0-10V.

Dimension and Installation Hole Dimension

Packaging Notice

Best DPF Series Specifications

General IconGeneral
BrandBest
ModelDPF Series
CategoryVentilation Hood
LanguageEnglish

Related product manuals