Sanitizer can be set to feed with the rinse (by
inputting a 0) or with detergent (by inputting
a 1).
0 = Sanitizer runs with rinse
1 = Sanitizer runs with detergent
2 = Sanitizer runs with rinse, low level
alarm stops pumps
3 = Sanitizer runs with detergent, low
level alarm stops pumps
4 = Sanitizer runs with rinse, pumps
continue running despite low level alarm
5 = Sanitizer runs with detergent, pumps
continue running despite low level alarm
Use the DATA UP and DATA DOWN keys to
select 1 or 0, then press SEND.
When set to run with rinse, the
sanitizer pump runs at the
selected speed during the delay
and the rinse cycle. When set to
run with detergent, the sanitizer
pump runs only when the
detergent pump runs.
Programming: Sanitizer Signal & Alarm
Logic
Ignore this menu if using a 2 product system without low level lance