PREPARE THE ELECTRICAL CONNECTION SYSTEM BETWEEN THE TRANSFORMER PANEL AND
THE DEIMOS BT A400/600, ACCORDING TO THE CABLE DATA INDICATED IN THE ATTACHED TABLE
CPEM WITH BT A400/A600 TRANSFORMER
Cable section (mm
2
) 1 mm
2
1.5 mm
2
2.5 mm
2
4 mm
2
Deimos 400
[0.116 Ohm]
5.5 m 8.3 m 13.8 m 22.1 m
Deimos 600
[0.0695 Ohm]
3.3 m 5 m 8.3 m 13.2 m
Cable section (AWG) AWG 17 AWG 15 AWG 13 AWG 11
Deimos 400
[0.116 Ohm]
5.5 m 8.3 m 13.8 m 22.1 m
Deimos 600
[0.0695 Ohm]
3.3 m 5 m 8.3 m 13.2 m
ASSEMBLE THE PANEL WITH TRANSFORMER AS PER THE MANUAL CONTAINED IN THE PACK
DEPENDING ON THE SECTION OF THE CABLE CHOSEN,
BREAK THE CABLE PASSAGE ZONE
OPEN THE COVER BY
UNSCREWING THE SCREWS