28
ASSE NELLA MANICA and JOLLY IRONING BOARD
ENGLISH
cable with one of the same type (available at the authorized
technical assistance). The replacement must be done only by
authorized personnel or by the technical assistance authorized
by the manufacturer.
22. The security stopper/security valve must be replaced every
once a year from the rst ignion.
23. Do not pour chemicals, acids, solvents, detergents, corrosive
or toxic substances, perfumes etc. inside the boiler, pour only
water.
24. Do not clean the machine by water spraying, do not dip into
water, use only a wet cloth with the machine o, unplugged
and cooled. Do not use any type of detergents.
25. Never touch the machine while plugged with wet hands and/
or barefoot.
26. Do not use the machine next to water (sinks, pools, bathtubs,
containers, etc.), in places with a certain danger of explosion or
presence of toxic/inammable substances.
27. Do not run steam jet towards people and/or animals and
electrical or electronic equipment plugged to the power grid.
28. The emptying of the boiler does not need to be done at the
end of each operang session, but boiler emptying/cleaning
must be done at least once a month. Before doing it, unplug the
machine, let it cool and gently unscrew half-round the security
valve to remove eventual residual pressure inside the boiler.
When the boiler is empty open gently the drain valve to let the
residual water get out. If no water comes out check the output
for limescale. In case of limescale inside the boiler, it is possible
to pour inside it a glass of water mixed with vinegar. Then shake
and empty the boiler, then rinse with water. It is recommended
not to use any an-limescale products.
29. While using the machine, the stopper/security valve must ne-
ver be removed.