General operational guidance and disclaimers.
Identification of warnings, personnel qualifications, and safe working.
Hazards associated with ignoring safety instructions.
Guidelines for safe operation, maintenance, and installation.
Rules on unauthorized modifications and unacceptable operational modes.
Overview of SC400 operating modes and primary features.
Electrical and physical specifications of the SC400.
Range of values for various programming parameters.
Overview of power, output, and input connections.
Details on terminal functions for various inputs and outputs.
How to connect power to the SC400 unit.
Details on the four fuses and their locations.
Connecting Valve A & B outputs for various system types.
Wiring for autofill pump and general input terminals.
Description of the eight primary input signals.
Description of the four secondary input signals.
Detailed descriptions of input terminals and their functions.
Explanation of fault signal relays and jumper link configuration.
Initial steps for system setup and timing configuration.
Setting up system parameters like language, type, and functions.
Settings for Dualine Electric systems, including valve feedback and pump power.
Configuration of low level, low pressure, and alarm 2 inputs.
Settings for input polarity and warning/fault relay operation.
Viewing input status, controlling outputs, and LCD contrast.
Setting operator/engineer passwords and resetting parameters.
Setting operation parameters for system timing.
Configuring pump mode, cycles, and time for progressive systems.
Setting air purge, monitor, overcount, and idle parameters.
Configuring idle settings and autofill pump functionality.
Configuring autofill timeout, lube at power up, and operation mode.
Setting idle modes, time, cycles, watchdog, and monitor time.
Setting pump mode, cycles, and time for Dualine Hydraulic.
Configuring monitor time for fault detection in Dualine Hydraulic.
Configuring idle settings, time, cycles, and watchdog functions.
Settings for autofill, lube at power up, and system operation.
Settings for pump mode, monitor time, and idle parameters.
Configuration of idle, watchdog, machine cycles, and autofill pump.
Configuring autofill timeout and lube at power up.
Setting the system to run mode after parameter setup.
Configuring monitor time, autofill, and power-up settings.
Setting the system to run mode.
Explanation of messages displayed on the SC400 LCD.
Details on warning events and their handling.
Details on various fault conditions like low level, pressure, and motor trip.
Explanation of monitor, watchdog, EEPROM, and autofill failure faults.
List of available technical data sheets for additional information.
List of part numbers for SC400 service components.
Wiring diagrams for single and dual zone progressive systems.
Wiring diagrams for single and dual zone injector systems.
Wiring diagrams for single and dual zone hydraulic systems.
Wiring diagrams for electric dualine systems with pressure switches.
| Type | Controller |
|---|---|
| Model | SC400 |
| Manufacturer | Bijur Delimon |
| Voltage | 24 VDC |
| Number of Zones | Up to 4 |
| Inputs | 4 Digital Inputs |
| Communication | RS-485 |