This document describes the SL1500ACL Premium Sliding Gate Opener, a device designed for automating single sliding gates in residential vehicular traffic (Class I). It emphasizes safety, proper installation, and maintenance for optimal performance and longevity.
Function Description:
The SL1500ACL is a motorized gate opener that automates the opening and closing of a single sliding gate. It operates using a chain drive system and is designed for vehicular traffic, with a strong recommendation for a separate access point for pedestrians to prevent contact with the moving gate. The system incorporates magnetic limit switches to define the gate's open and closed positions, and a collision reaction system (Type A entrapment protection) for safety. It can be controlled via remote controls, with options for single-button or four-button operation. An infrared sensor set is included for additional non-contact entrapment protection (Type B1). The device also features an optional autoclose function and a movement alarm.
Important Technical Specifications:
- Model: SL1500ACL
- Input Power: 110-120 V~60Hz
- Rated Power: 0.74 hp (550 W)
- Torque: 23.6 lb.-ft. (32 N-m)
- Duty Cycle: S2 20 min.
- Max. Gate Weight: 3300 lb. (1500 kg / 1.65 T / 1.5 MT)
- Max. Gate Speed: 42.5 fpm (13 m/min.)
- Chain Type: ANSI #41
- Provided Chain Length: 20 ft. (6 m)
- Max. Gate Length: 40 ft. (12 m)
- Max. Noise: 60 dB
- Min. Temperature: -4°F (-20°C)
- Max. Temperature: 158°F (70°C)
- Weatherproofing: IP44
- IR Signal: 940 nm 1.9 kHz
- IR Sensor Range: 6.6-65.6 ft. (2-20 m)
- Max. Remotes: 25
- Remote Range: 98.4 ft. (30 m)
- Remote Frequency: 433.92 MHz
- Power Cord Length: 4 ft. 11 in. (1.5 m)
- Gate Opener Dimensions: 19.3 in. (49 cm) height, 11.8 in. (30 cm) width, 9.1 in. (23.2 cm) depth.
- Mounting Plate Dimensions: 10.9 in. (27.6 cm) length, 3.3 in. (8.5 cm) width, with Ø0.59 in. (15 mm) bolt holes.
Usage Features:
- Initial Testing and Setup: Before full installation, the motor's manual release keys allow for manual gear rotation testing. The motor's operation can be confirmed with provided remote controls, which are pre-paired. The default setting is single-button control, cycling through OPEN→STOP→CLOSE→STOP. The direction of operation (right or left side installation) can be reversed via a DIP switch.
- Magnetic Limit Switches: These define the gate's open and closed positions, ensuring the gate stops gently at the desired locations. Magnets are installed on the gate posts at specific heights relative to the taut chain.
- Infrared Sensors: An infrared sensor set (Z) provides additional safety by detecting obstructions in the gate's path. These sensors should be placed on opposite sides of the gate, 6'7" (2 m) to 40 feet (12 m) apart, and connected to the motor's circuit board.
- Adjustable Settings:
- Obstruction Sensitivity (VR1): Controls how sensitive the gate is to obstructions, allowing for adjustment to prevent overreaction to minor issues like strong winds.
- Braking Force (VR2): Adjusts the motor's braking strength.
- Slow Stop Distance (VR3): Controls the sensitivity to limit switches, affecting how gently the gate stops.
- Starting Force (VR4): Adjusts the initial force of the gate's movement.
- DIP Switches:
- Deactivate Slow Start (DIP1): Disables the gradual speed-up, though not recommended for system longevity.
- Reverse Direction (DIP2): Changes the gate's operating direction for left or right side installation.
- Autoclose Time (DIP3 & DIP4): Configures the gate to automatically close after 12, 24, or 36 seconds, or disables autoclose for manual closure.
- Deactivate Collision Close (DIP5): Disables automatic closure upon collision detection (not recommended).
- Remote Operation Mode (DIP6): Switches between single-button (default) and four-button remote operation.
- Remote Pairing: Up to 38 additional remotes or wireless control buttons (433.92 MHz) can be paired. The pairing process involves pressing a button on the circuit board and then on the remote. All stored remotes can be unpaired simultaneously by holding the pairing button until the indicator light turns off.
- Movement Alarm: The circuit board produces an audible alarm when the motor is active, which can be deactivated if desired (not recommended for safety).
- Power Connection: Requires a stable, compatible, and well-grounded power source, with the outlet protected from elements and equipped with a GFCI, RCD, or circuit breaker. Wiring should ideally be run underground in PVC pipe.
Maintenance Features:
- Regular Inspection: Periodically check the gate's track for grime and debris, and confirm smooth manual operation.
- Component Check: Do not use if any component is missing, loose, worn, or damaged. Tighten, repair, or replace problematic parts with identical components.
- Electrical Connections: Ensure adequate insulation and protection of all electrical connections. Never direct pressurized water against the device.
- Chain and Track: Keep the chain and track clean and free of corrosion, grime, or obstructions.
- Lubrication: Lubricate wheels and rollers as needed.
- Monthly Testing: If not in regular use, test the gate opener at least once a month. Manually test the gate's smooth movement after disconnecting power and unlocking the gate.
- Professional Assistance: Only trained technicians should install and repair the device and its electrical connections. Consult a professional electrician for complex wiring or voltage drop issues.
- Safety Warnings: Always supervise children and pets near the gate. Keep controls out of reach of children. Never pair a remote to multiple devices or attempt to operate with multiple remotes simultaneously. Disconnect power before any wiring adjustments or maintenance, except for specific testing instructions.