This document is a user manual for the SL600ACL Premium Sliding Gate Opener. It provides detailed instructions for installation, setup, adjustment, and troubleshooting, along with important safety information and technical specifications.
Function Description:
The SL600ACL Premium Sliding Gate Opener is designed for automating single sliding gates used for Class I residential vehicular traffic. It operates by moving a gate along a track using a chain and sprockets, controlled by remote controls or other access systems. The opener includes safety features such as a collision reaction system (Type A entrapment protection) and support for infrared sensors (Type B1 non-contact sensor) to prevent accidents. It can be configured for either right-side or left-side gate operation and offers single-button control or four-button control modes. The system also includes magnetic limit switches to define the gate's open and closed positions and an optional autoclose function.
Important Technical Specifications:
- Model: SL600ACL
- Input Power: 110-120 V~60Hz
- Rated Power: 0.37 hp (280 W)
- Torque: 11.8 lb.-ft. (16 N-m)
- Duty Cycle: S2 20 min.
- Max. Gate Weight: 1400 lb. (600 kg / 0.7 T / 0.6 MT)
- Max. Gate Speed: 42.5 fpm (13 m/min.)
- Chain Type: ANSI #41
- Provided Chain Length: 20 ft. (6 m)
- Max. Gate Length: 40 ft. (12 m)
- Max. Noise: 56 dB
- Temperature Range: -4°F to 158°F (-20°C to 70°C)
- Weatherproofing: IP44
- IR Signal Frequency: 940 nm (1.9 kHz)
- IR Sensor Range: 6.6-40 ft. (2-12 m)
- Max. Remotes: 40
- Remote Range: 98.4 ft. (30 m)
- Remote Frequency: 433.92 MHz
- Power Cord Length: 4 ft. 11 in. (1.5 m)
- Motor Dimensions: 19.3 in. (49 cm) height, 11.8 in. (30 cm) width, 9.1 in. (23.2 cm) depth.
- Mounting Plate Dimensions: 10.9 in. (27.6 cm) length, 3.3 in. (8.5 cm) width.
Usage Features:
- Single-Button Control: Default mode where one button cycles through OPEN→STOP→CLOSE→STOP.
- Four-Button Control (Optional): Allows separate buttons for OPEN, STOP, and CLOSE commands.
- Adjustable Obstruction Sensitivity (VR1): Controls how sensitive the gate is to obstructions, preventing overreaction to minor issues like wind or leaves.
- Adjustable Braking Force (VR2): Controls the motor's braking force, affecting how quickly it stops.
- Adjustable Slow Stop Distance (VR3): Controls the sensitivity to limit switches, affecting the gate's stopping point.
- Adjustable Starting Force (VR4): Controls the gate's initial force when starting movement.
- Soft Start (DIP Switch 1): Default setting for gradual acceleration to minimize wear (can be deactivated).
- Reverse Direction (DIP Switch 2): Allows configuration for right-side or left-side gate installation.
- Autoclose Function (DIP Switches 3 & 4): Configurable delays (12, 24, or 36 seconds) for automatic gate closure after reaching the maximum open position. Manual closure is the default.
- Movement Alarm: The circuit board produces a buzzing noise when the motor is active (can be deactivated).
- Infrared Sensors (W): Provides non-contact entrapment protection, stopping the gate if the beam is broken.
- Manual Release Keys (B): Allows manual operation of the gate by disengaging the motor's locking mechanism.
- Remote Pairing: Supports pairing up to 40 remote controls or wireless control buttons.
- Remote Unpairing: All stored remotes can be purged from memory.
Maintenance Features:
- Weatherproof Components: All provided components are designed to withstand normal rain.
- Regular Inspection: Periodically confirm smooth manual operation, check for missing, loose, worn, or damaged components.
- Cleanliness: Keep gear and guide tracks clean and free of corrosion, grime, or obstructions.
- Lubrication: Lubricate wheels and rollers as needed.
- Monthly Operation Test: If not in regular use, test the gate opener's operation at least once a month.
- Component Replacement: Only replace problematic parts with identical components and fully replace damaged electrical cords.
- Professional Electrical Work: Only trained and licensed electricians should perform rewiring or electrical repair work.
- Safety Disconnection: Always disconnect power before removing covers or making wiring adjustments, except for remote pairing.