- Dry
When this function is set, the "Dry" light on the
control panel illuminates; the fan speed is fixed at
the minimum level and cannot be modified. The
appliance does not cool the room when the dry
function is activated. When this function is used,
continuous drainage must always be provided to
ensure the maximum drying efficiency. Make sure
that the rubber plug of the bottom drainage hole (9)
is positioned correctly. Undo the ring-nut of the
continuous drainage hole by turning it anticlockwise,
and remove the plug of the top drainage hole.
Connect the hose with internal diameter 10 mm and
length 30 cm max. (supplied with some models) to
the continuous drainage hole (14); make sure that
the connection is watertight.
Check that the drain is at a lower level than the spout and that the hose is placed with a constant
gradient, lower than the spout at all times. If continuous drainage is not being used, remove the
drain hose and fit the plug with its nut.
- Fan
When this function is set, the "Fan" light on the control panel illuminates; the selected speed (low/hi)
is changed at every press on the button.
DRAINAGE
In
“Cool”
mode, the appliance vaporises the condensate automatically. When the unit is operating
in cool mode, make sure that the rubber plugs that seal the drainage holes (bottom & top) on the
rear are fitted correctly.
When the appliance is operating in “
Cool”
mode, there is no need to connect the
continuous condensate drainage; water will not build up inside the unit except in
particular weather conditions with a very high humidity level.
When the container is full, the "Water full" light comes on to indicate this and the
appliance cuts out.
To empty the container, switch off the appliance and remove the plug from the socket. Place the
end of the drain over a container to collect the condensate, undo the nut, and remove the plug of
the bottom drainage hole.
USE
Do not leave the air-conditioner in operation for long periods with high humidity and open doors
or windows. The humidity might condense, wetting or damaging furnishings.
For optimal air-conditioning and efficiency, doors and windows must always be closed.
In: Cool or Fan modes, check that the drainage plugs are fitted correctly.
If continuous drainage is in use, make sure that the drainage hose is properly connected to the
spout, that the opposite end is lower than the spout, and that the incline is even, so that the water
flows internally without any obstructions.
Caution: do not cover the appliance to avoid overheating.
Before each use, make sure that:
-the appliance is in good condition
-that the power cable and flexible pipe are not damaged
Open the horizontal flaps manually in the desired direction.
Connect the plug to the power socket; you will hear a beep.
Turn on the appliance, press the “POWER” button and activate the functions required, proceeding
as described above.
Press thePOWER” button to deactivate the appliance: it switches to stand-by mode. To switch
it off completely, the plug must be removed from the power socket.