Maintenance:
UV-C lamps should be replaced on an annual basis. While there still may be a visible blue light, this is not an indication of UV-C output (the
UVC wavelength is invisible). Contact your local Bio-Shield UV-C Air Sanitizer ™ distributor or visit www.UvcAirSanitizer.com/
Lamp part numbers: J-TUV20WT5 4P.SE (Standard 17” Lamp) or J-TUV16WT5 4P.SE (12” Lamp)
EQUIPMENT WARRANTY
Joneca Corporation warrants to the original buyer that its Products shall be free from defects in material or workmanship under normal use and service for the
periods of time set forth below. This warranty is contingent upon proper use of Products and will not apply if adjustment, repair or parts replacement is required
because of an accident, unusual physical, electrical or electro-mechanical stress, neglect, misuse, failure of electric power, humidity control, transportation,
unauthorized repair actions, or not installed or maintained in accordance with Joneca Corporation’s specifications hereunder, or where Product serial numbers
have been altered, defaced, or removed. Joneca Corporation’s obligation under this warranty shall not arise until the Purchaser of the Product returns the
defective part to Joneca Corporation or their authorized retailer or distributor. This warranty is limited to the repair and/or replacement of parts. This warranty
does not cover any labor or subsequent damage incurred as the result of Product failure or indirectly arising from the design, construction, installation, servicing,
or operation of Products. Joneca Corporation’s and its resellers’ liability under this warranty shall in no event exceed the cost of goods sold under the original
sale contract.
Under the conditions specified above, Joneca Corporation warrants all Product fixtures for a period of two (2) year from date of purchase and all lamps for a
period of 12 months from date of installation provided lamps are installed within 3 months from date of purchase. Buyer must provide proof of purchase. This is
Joneca Corporation’s sole warranty. No warranties are extended beyond those described herein and it is expressly agreed that this warranty will be in lieu of
all warranties of fitness and merchantability. Joneca Corporation neither assumes, nor authorizes any person to assume for it, any obligation in connection with
the Products. Buyer shall not return to Joneca Corporation any allegedly defective goods without Joneca Corporation’s prior written authorization. This warranty
may not be assigned or transferred.
Joneca Corporation
4332 E. La Palma Ave.
Anaheim, CA. 92807
CUSTOMER SERVICE: 888-8JONECA (1-888-856-6322) FAX: 714-993-2126
www.Joneca.com
Specifications subject to change without notice. © Joneca Corporation 2014, All Rights Reserved
IMUVC142
GENERAL INSTALLATION INSTRUCTIONS
CAUTION! Never Expose Eyes or Skin directly to UV-C
Read all Materials before Starting.
Application:
The Bio-Shield UV-C Air Sanitizer™ delivers 20 watts of sanitizing UV-C power to heating and air conditioning units that are
circulating air throughout the home. Its lamp and socket are water-resistant, and because it is powered by a 24V converter without
danger of shock, fire or code issues becomes quite simple. It also makes for a safe and affordable installation that meets most electrical
codes. The Bio-Shield Air Sanitizer™ installs from the exterior of HVAC equipment. Simply create a 2 7/8” insertion hole (with the hole saw
provided) at the intended site, mount the fixture and plug it to a suitable 110-120 volt wall outlet.
Fixture is meant to operate
continuously (24/7/365) to avoid growth of mold and bacteria, etc. under optimum conditions even when A/C-Heating
unit itself is off.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance, or use can cause fire, electrical shock, or other conditions which may
cause personal injury or property damage. If you have questions or difficulty in installation please consult with Joneca Corporation for
information or assistance. Follow all safety codes, wear safety glasses and work gloves. Read all instructions thoroughly
Understand the signal words DANGER, WARNING or CAUTION. These words are universally used for overall safety. DANGER identifies the
most serious hazards, which will result in severe personal injury or death. WARNING signifies hazards, which could result in personal injury
or death. CAUTION is used to identify unsafe practices, which would result in minor personal injury or product and property damage.
WARNING: Before installing or servicing this unit, turn off all power to both the heating/air conditioning unit and the wall outlet into which the
Bio-Shield Air Sanitizer™ will be plugged. There may be more than one (1) switch.
General:
1. Bio-Shield Air Sanitizer™ Fixtures can be used to bathe surfaces, the air or both with UV-C energy. The most common area for
installation is in the supply duct and mixed air plenums (ductwork) or any combination of locations. If installed on the return side, it
should be at least 18” from any filter. For a more Advanced Installation: if it is known exactly where the coils, refrigerant line, fan,
drain pan and other component are located, and the installation hole can be drilled without affecting any of these or other components,
the Bio-Shield Air Sanitizer™ can be installed near any of those components. Joneca Corporation is not responsible for any damage
to HVAC if installation is installed in Advanced Installation areas.
2. Check first for power availability of an 110V-120V wall socket.
Power Ratings:
The BIO-SHIELD UV-C AIR SANITIZER™ is rated at 24V AC/DC-50/60Hz, 1Amp which is stepped down from the 110V-120V wall outlet by
a 24V Adapter.
Question and Answer IconNeed help?

Do you have a question about the Bio-shield UV-C Air Sanitizer and is the answer not in the manual?

Bio-shield UV-C Air Sanitizer Specifications

General IconGeneral
BrandBio-shield
ModelUV-C Air Sanitizer
CategoryAir Cleaner
LanguageEnglish

Summary

Maintenance

Register Your Bio-Shield UV-C Air Sanitizer

Registration Information

Form to register the UV-C Air Sanitizer for lamp replacement reminders.

Equipment Warranty

Details warranty coverage, conditions, and limitations for the product and its components.

General Installation Instructions

Application

Explains the purpose and operation of the UV-C Air Sanitizer in HVAC systems.

Safety Considerations

Highlights critical safety precautions and warnings for installation and use.

General Installation

Provides general installation guidelines and location recommendations for the UV-C fixture.

Power Ratings

Specifies the power requirements and voltage conversion for the UV-C Air Sanitizer.

Installation for Metal Ductwork and Plenum

Connecting Power

Details how to connect the 24V AC/DC adapter to a 110V-120V wall socket.

UV-C Lamp Replacement Instructions

Step-by-step guide for removing and installing UV-C lamps.

Used UV-C Lamp Disposal