BMMT CC#2017-009, Effective Date: 26Jan2018 MA056-ART01-D v8.8
Mechanical Testing System
Mach-1
User Manual
Version 8.8
Biomomentum Inc.
970 Michelin Street, Suite 200
Laval, Quebec, Canada, H7L 5C1
(+1) 450-667-2299
www.biomomentum.com
Designed and Assembled in Canada
MA056
Question and Answer IconNeed help?

Do you have a question about the Biomomentum Mach-1 and is the answer not in the manual?

Summary

Introduction

System Description

Hardware

Describes the components of the Mach-1 Micromechanical System.

Software

Explains the Mach-1 Motion software and its functions.

Terminology

Defines key terms used within the Mach-1 Motion environment.

Computer System Requirements

Safety Recommendations

System Installation

Software Installation

Guides through the process of installing the Mach-1 Motion software and drivers.

Hardware Installation

System Activation

Hardware Initialization

Mach-1 Motion Software Usage

Setup & General Information

Covers software interface elements and general system information.

Acquisition Rate Configuration

Explains how to set the data sampling rate for stages and load cells.

Manual Controls

Axis Selection

Selects the stage axis for manual control operations.

Velocity Control

Sets manual control speed for stage movement.

Stage Movement Controls

Utilizes buttons for manual stage displacement and power control.

Axis Midpoint Function

Finds and sets the axis midpoint as a reference point.

Axes Power Control

Controls the power status of stage motors.

Load Cells

Load Cell Calibration Procedure

Details the procedure for calibrating load cells with known weights.

Low-Pass Filter Settings

Analog Inputs Configuration

User Manual Access

About Software;Hardware

Camera Feed Add-On

Camera Feed Operations

Covers snapshot, recording, and settings for the camera feed.

Mach-1 Status Monitoring

Closing Mach-1 Motion

Function Library

Creep Function

Details parameters for studying deformation under constant load.

Find Contact Function

Explains detecting sample surface or bottom with stage movement.

Stage Repositioning Options

Details stage repositioning after reaching contact criteria.

Move Absolute Function

Describes moving the stage to a specific absolute position.

Move Relative Function

Explains moving the stage by a specified relative amplitude.

Normal Indentation Function

Details surface detection and testing via indentation.

Paraboloid Function

Describes ramp and release routines for stage movement.

Ramp-Release Function

Explains executing ramp, relaxation, and release sequences.

Scan Function

Describes moving stages to predefined positions for automated scanning.

Sinusoid Function

Explains executing precise sinusoidal displacements.

Stress Relaxation Function

Details ramp-hold displacements for stress relaxation tests.

Wait Function

Acquires data without activating motors for a specified duration.

Zero Load and Zero Position

Sets load cell and stage position readings to zero.

Saving Test Results

Guides on how to save test data to files.

Acceleration Notes

Provides information on automatic acceleration/deceleration settings.

Sequence Management

Function Management in Sequences

Describes adding, deleting, and reordering functions within a sequence.

Sequence Execution

Details how to start, run, and interrupt a defined sequence.

System Configuration

Hardware Setup

Configures communication parameters between computer and controller.

Stage Velocities Configuration

Stage PID Configuration

Advanced PID Parameters

Details PID parameters and their effect on servo loop performance.

Single-Axis Load Cell Configuration

Single-Axis Load Cell Calibration

Multiple-Axis Load Cell Configuration

Multiple-Axis Load Cell Calibration

Reset Configuration Settings

System Specifications

Troubleshooting

Cleaning, Preparation, and Maintenance

General Cleaning and Maintenance

Describes regular cleaning procedures for the system's exterior and components.

Preparation Prior Testing

Steps to prepare the system before starting a test session.

Cleaning After Testing

Procedures for cleaning the system and accessories after use.

Explanation of Symbols

List of Related SOPs

Software Licensing Agreement

Extent of Limited Warranty

Catalog Overview

Servicing and Technical Support

Contact Information

Biomomentum Mach-1 Specifications