4
To operate your air purier:
1. Plug into an electrical outlet.
2. Press the power button ( ). The air purier
will turn onto HIGH, the power light and the
High (3) speed indicator light will illuminate
letting you know the power is on and running
at High setting. To turn the air purier off
at any time, press the power button and all
indicator lights will go off.
3. You can then select the desired speed
setting. This air purier has three speed
settings. You can select from HIGH (3),
MEDIUM (2), or LOW (1) by pressing the
desired operating speed control button on the
control panel. The corresponding indicator
light will illuminate to indicate which setting
being selected.
4. To release negative ions into the ltered air,
press the ioniser button ( ) and the indicator
light will illuminate.
NOTE: The ioniser will not work unless the
unit is running.
5. To activate the Night Light at any speed
setting, press the night light button ( ) to
illuminate. Press the button again, the night
light will go off.
CLEANING AND MAINTENANCE
1. Turn the air purier off and unplug it before
cleaning.
2. The outside of the air purier can be cleaned
with a soft, clean dampened cloth.
3. The base air inlet grill can be removed and
washed in warm soapy water (not dishwasher
safe). Dry before replacing in the unit.
4. The ltered air outlet can be cleaned of dust
with a small, soft brush.
5. If you wish to clean the inside lter chamber,
please only use a dry, soft cloth to wipe it
down.
WARNING: Do not allow moisture to come
in contact with the main housing of the air
purier.
Cleaning The Permanent HEPA-type
Filter
IMPORTANT:
• If the lter is enclosed in plastic bag, remove
it before use.
NOTE: Every few weeks, check the condition
of lter. Filter life will vary, depending on air
quality and usage. Under normal conditions of
continuous use, the HEPA-type lter will operate
efciently for 3-4 months, but we recommend
regular cleaning for optimal performance.
After approximately 4 months of operation, the
Filter Service Indicator will will illuminate (yellow
LED) to alert you to clean lter before further use.
To remove the lter for cleaning:
1. Turn off and unplug the air purier.
2. To open and release the base air inlet grill
from the base, locate the handle at the base
grill and turn counter-clockwise until the
Unlock icon ( ) is aligned with the indicator
mark below the power cord outlet on the rear
side of the air purier housing (see Figure 2).
3. Take out the permanent HEPA-type lter from
the unit, check the condition of the lter, and
remove for cleaning if dirty.
4.
Using your vacuum cleaner, run the brush
attachment along both sides of the lter and
clean between the pleated layers (see Figure 3).
Figure 3
Air Purier Housing
Base Grill Handle Air Inlet Grill
Figure 2
Take out Permanent
HEPA-type Filter for
cleaning
RELEASE