Enitra 6/8 Pr oMRI
®
Pacemaker | Bradyarrhythmia Therapy |
Cardiac Resynchronization Therapy
Technical Manual
417801
Revision: B (2016-03-23)
© BIOTRONIK SE & Co. KG
All rights reserved.
Specification subject to modification, revision and improvement.
® All product names in use may be trademarks or registered trademarks held
by BIOTRONIK or the respective owner.
Index 417801Technical ManualEnitra 6/8
0123 2016
BIOTRONIK SE & Co. KG
Woermannkehre 1
12359 Berlin · Germany
Tel +49 (0) 30 68905-0
Fax +49 (0) 30 6852804
sales@biotronik.com
www.biotronik.com
Question and Answer IconNeed help?

Do you have a question about the BIOTRONIK Enitra 8 HF-T and is the answer not in the manual?

BIOTRONIK Enitra 8 HF-T Specifications

General IconGeneral
Device TypeImplantable Cardioverter Defibrillator (ICD)
ManufacturerBIOTRONIK
Maximum Energy Output40 J
Battery ChemistryLithium Silver Vanadium Oxide
Remote Monitoring CompatibilityBIOTRONIK Home Monitoring
ProgrammingBIOTRONIK Programmer
Bradycardia Pacing ModesDDD, VVI, DDDR
MRI ConditionalYes
IndicationsHeart failure

Summary

General Safety Instructions

Possible Complications

Possible Risks

Procedures to Avoid and Potentially Risky Procedures

Procedures that may harm the patient or damage the device.

External Defibrillation and Radiation Therapy

Risks associated with external defibrillation and radiation therapy.

Magnetic Resonance Imaging (MRI) Risks

Risks and precautions for MRI procedures with implanted devices.

Implantation

Implantation Procedure Overview and Preparation

Steps for implantation, required parts, and unpacking procedures.

Precautionary Measures while Programming

System Checks, Patient Monitoring, and Telemetry

Procedures for checking the device system and monitoring the patient.

Critical Settings and Sensitivity

Avoiding critical parameter settings and manual sensitivity adjustments.

Preventing Complications and Risks

Measures to prevent device-induced complications, atrial tachycardia, and risks with LV pacing.

Parameters

Timing: Basic Rate, Hystereses, AV Delay

Configuration options for timing parameters like basic rate, AV delay, and hystereses.

Ventricular Pacing Parameters

Settings for ventricular pacing, triggering, and suppression.

Upper Rate and Mode Switching

Configuration of upper rate limits and mode switching behavior.

Refractory Periods and Blanking Periods

Settings for refractory and blanking periods to manage sensing and pacing.

Pacing and Sensing Parameters

Settings for pulse amplitude, pulse width, sensitivity, and capture control.

Rate Adaptation Parameters

Configuration of rate adaptation features like CLS and accelerometer-based modes.

MRI Program Parameters

Settings for MRI modes and parameters to ensure safety during MRI scans.

Preset Programs and Tolerances

Overview of preset programs and tolerances for parameter values.

Technical Data

Mechanical Characteristics

Physical dimensions, volume, and mass of the device housing.

Electrical Characteristics

Electrical properties, circuit technology, and conductive surface area.

Battery Data and Service Times

Battery characteristics, power consumption, and estimated service times.

Related product manuals