Presettings
Operating instructions GLP
3 -- 77
6.562.98.5.01.18
USA -- USDA standardized
Valid for all meat and poultry products.
Control and selection of the packages according to the guidelines of the Hand-
book 133.
If “USA -- USDA standardized” has been selected (see page 3 -- 69), presettings
for “USA -- USDA standardized”” can be entered after calling up Package selec-
tion.
Operating sequence: Description
------------------------------------------------------------------------------------------------------------------------------------------------------
[MODE] 2
Processing Wgt class
statistics
Package
selection
-- Call up the selection menu.
USA -- USDA standardized
Nominal weight
TO
TU1
200 g
244 g
Select. acc. to
189 g
Too light
Good
Too heavy
Do not eject
Package ejector
Package ejector
0 g
0 g
0 g
Nominal weight:
xxxx [ENTER] --
Enter respective nominal package weight and confirm.
TO: The upper tolerance limit is preset according to the Handbook
133, but can be changed manually, if required.
or [ ] -- Possibly select input field for TO.
xxxx [ENTER] --
Possibly enter different tolerance limit TO and confirm.
TU1: The upper tolerance range TU1 is preset according to Hand-
book 133 and can not be changed.
or [ ] [ ] -- Possibly select input field for TO.
Too light: No presetting necessary with GLP !
Good: No presetting necessary with GLP !
To heavy: No presetting necessary with GLP !
Store presettings: see page 3 -- 100
3.