Maintenance
Operating instructions GLP
4 -- 12
6.562.98.5.01.18
4.2.4 Replacing the fuse
-- Before replacing the mains fuse, first discon-
nect the power cable from the labeler.
-- The mains fuse is located above the power
switch on the device rear side.
-- Slightly press on the fuse holder using a
screw driver and turn it to the left by 90 de-
grees until it disengages.
-- Remove the fuse holder, remove the defec-
tive fuse and replace it by the same type
(identical ratings).
-- Reinsert the fuse holder with the guiding
nose facing downward, press it in using a
screw--driver and turn it to the right by 90 de-
grees.
-- Plug in the power cable and switch on the la-
beler.
-- Provide a new spare fuse. For fuse ratings,
see nameplate.
4.2.5 Description of the identification plate
The type of plate and data indicated vary from country to country. The most impor-
tant data is explained in the following examples.
4.2.5.1 Weighing range identification plate affixed to the operating ter-
minal GT 240
Weighing range plate affixed to the operating terminal to the left of the operating
terminal.
4.2
Mains fuse
Power switch
Power outlet
0
1
Max 6 kg
Min 40 g
e = 2 g
Max maximum capacity of the scale
Min minimum load of the scale
e = verification scale interval of the scale