Loading...
Compresor de Aire Lubricado
Compressor de Pistão à Óleo
Lubricated Air Compressor
CT24
CT50
MANUAL DE INSTRUCCIONES
MANUAL DE INSTRUÇÕES
INSTRUCTIONS MANUAL
ADVERTENCIA: LEASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO.
ADVERNCIA: LEIA ESTAS INSTRUÇÕES ANTES DE USAR O PRODUTO.
WARNING: READ INSTRUCTIONS MANUAL BEFORE USING PRODUCT.
Español 5
Português 9
English 13

Questions and Answers

  • S
    Sandra ManningAug 6, 2025
    Why does my Black & Decker CT24 Air Compressor keep stopping and starting?
    • J
      Justin ElliottAug 6, 2025
      If your Black & Decker Air Compressor stops and restarts automatically after a few minutes, it's likely due to the thermal cutout tripping from the motor overheating. To resolve this, clean the air ducts in the conveyor, ensure the work area is well-ventilated, and reset the thermal cutout. For lubricated models, also verify the oil level and quality.
  • M
    Mike EvansAug 12, 2025
    What to do if my Black & Decker CT24 stops after a few attempts to restart?
    • S
      stephanie33Aug 12, 2025
      If, after several restart attempts, your Black & Decker Air Compressor stops, it's probably because the thermal cutout is tripping due to the motor overheating. This can happen if the plug is removed while the compressor is running or due to low power voltage. Turn on the on/off switch, ensure the work area is ventilated, and wait a few minutes for the compressor to restart automatically. Also, remove any power cable extensions.
  • J
    Jade SchneiderAug 17, 2025
    Why is my Black & Decker CT24 Air Compressor losing pressure and starting up frequently?
    • N
      Nicole HooverAug 18, 2025
      Reduction of performance, frequent start-up and low pressure values in your Black & Decker Air Compressor can be caused by excessive performance request, leaks from the couplings and/or pipes, or a clogged intake filter. Try replacing the seals of the fitting and cleaning or replacing the filter.
  • R
    robin08Aug 25, 2025
    What to do if my Black & Decker Air Compressor won't stop and the safety valve is tripped?
    • K
      kstewartAug 25, 2025
      If your Black & Decker Air Compressor doesn't stop and the safety valve is tripped, unplug it and contact the Service Center. This issue indicates irregular functioning of the compressor or breakage of the pressure switch.
  • M
    michaelgarciaAug 29, 2025
    How to fix air leakage from the valve of my Black & Decker CT24 when it's off?
    • M
      millerbarbaraAug 30, 2025
      If air leaks from the pressure switch valve when your Black & Decker Air Compressor is off, the check valve may not be working correctly due to wear or dirt on the seal. Unscrew the hexagonal head of the check valve, clean the valve seat and the rubber disk (replace if worn), then reassemble and tighten carefully.

Summary

Before Use

Environment and Usage Conditions

Use in a suitable, well-ventilated environment, away from dust, acids, vapors, or flammable gases.

Safety Distance and Work Area

Maintain a minimum 4m safety distance from the work area.

Power Cable and Socket Connection

Connect the plug to a suitable socket. Use short, appropriate extension cables.

Compressor Placement and Movement

Place on a stable, horizontal surface and use the handle for moving.

General Safety Instructions

Air Jet Direction and Eye Protection

Never direct air jet at people or animals. Wear safety goggles.

Handling and Environmental Precautions

Avoid wet conditions, pulling the cable, and exposure to weather.

Operator and User Restrictions

Keep children/animals away. Not for users with reduced capabilities.

Operational and Material Safety

Keep flammable items away. Clean with damp cloth. Use only for air.

Operation

Duty Cycle and Thermal Protection

Designed for intermittent use with automatic thermal cutout for motor protection.

Restart and Pressure Switch Operation

Follow specific procedures for restarting and understand pressure switch functions.

Safety Features and Gauge Reading

Note safety valve function and correct interpretation of the pressure gauge.

Tool Connection and Application Safety

Ensure air flow is off when connecting tools and follow application-specific safety.

Assembly Instructions

Wheel and Rubber Foot Installation

Assemble the wheels and fit the rubber stopper as per figures.

Air Filter and Oil Plug Fitting

Install the air filter and oil plug correctly after removing shipping plugs.

Voltage Requirements

Start-Up and Usage

Electrical System Compatibility

Verify system voltage and check oil level before initial start-up.

Automatic Operation and Pressure Regulation

Understand the automatic start/stop cycle and how to adjust air pressure.

Maintenance

Pre-Maintenance Safety

Always disconnect power and drain the receiver before performing any maintenance.

Component Checks and Filter Maintenance

Check screw tightness and maintain the intake filter regularly.

Oil and Condensate Management

Schedule oil changes, check levels, drain condensate, and dispose of fluids properly.

Authorized Service and Repairs

For non-manual adjustments, use authorized service centers with genuine parts.

Cleaning and Accessories

Housing Cleaning Procedure

Clean the compressor housing with dry air, using appropriate safety gear.

Accessory Usage Guidelines

Use only recommended accessories; unapproved ones can be hazardous.