EasyManua.ls Logo

Blain Hydraulics EV 100 - User Manual

Blain Hydraulics EV 100
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Oct 02
Printed in Germany
BLAIN HYDRAULICS GmbH Boellinger Hoefe D-74078 Heilbronn Tel. +49 7131 28 21-0 Fax +49 7131 485216 www.blain.de info@blain.de
EV 100 Service Manual
EN ISO 9001
Service Manual
Elevator Valve EV 100
1 3/4 Cross Section Diagrams of Valve
2 1 1/2 - 2 Section Diagrams of Valve
3 + 4 Quick Adjustment Procedure
5 EV Parts List
6 EV Trouble Shooting, Up Travel
7 EV Trouble Shooting, Down Travel
8 KS Slack Rope Valve Purpose and Adjustment
9 Down Leveling Adj. 9, Replacement
10 Overheating of Power Unit. System Leakage
11 Switches, Slow Down Distances
12 Flow-Pressure-Tables (metric), EV 100 Size Selection
13 Flow-Pressure-Tables (USA)
Page
Blain Hydraulics GmbH
Pfaffenstr. 1  Boellinger Hoefe  D-74078 Heilbronn  Germany
Tel. +49 7131 2821-0 Fax +49 7131 48 52 16 www.blain.de info@blain.de
Manufacturer of the Highest Quality:
Control Valves for Elevators
Tank Heaters - Hand Pumps - Pipe Rupture Valves - Ball Valves
Question and Answer IconNeed help?

Do you have a question about the Blain Hydraulics EV 100 and is the answer not in the manual?

Summary

Quick Adjustment Procedure: Up Travel

Up Travel Adjustment Steps

Detailed steps for adjusting up travel parameters.

Quick Adjustment Procedure: Down Travel

Up Travel Fine-Tuning and Pressure Relief

Adjustments for up deceleration, soft stop, and pressure relief.

Down Travel Adjustment Steps

Detailed steps for adjusting down travel parameters.

EV Parts List and Identification

Trouble Shooting: Up Travel

Issues with Starting Up Travel

Diagnosing and resolving problems with the elevator not starting up.

Problems with Up Travel Speed and Deceleration

Troubleshooting issues related to up travel speed and deceleration.

Trouble Shooting: Down Travel

Issues with Starting Down Travel

Diagnosing and resolving problems with the elevator not starting down travel.

Problems with Down Travel Speed and Sinking

Troubleshooting issues related to down travel speed and sinking.

Slack Rope Valve K

Down Leveling Adjustment 9

Overheating and System Leakage

Causes and Solutions for Power Unit Overheating

Identifying overheating causes and providing solutions.

Switch Distances for Landing and Stopping

Summary

Quick Adjustment Procedure: Up Travel

Up Travel Adjustment Steps

Detailed steps for adjusting up travel parameters.

Quick Adjustment Procedure: Down Travel

Up Travel Fine-Tuning and Pressure Relief

Adjustments for up deceleration, soft stop, and pressure relief.

Down Travel Adjustment Steps

Detailed steps for adjusting down travel parameters.

EV Parts List and Identification

Trouble Shooting: Up Travel

Issues with Starting Up Travel

Diagnosing and resolving problems with the elevator not starting up.

Problems with Up Travel Speed and Deceleration

Troubleshooting issues related to up travel speed and deceleration.

Trouble Shooting: Down Travel

Issues with Starting Down Travel

Diagnosing and resolving problems with the elevator not starting down travel.

Problems with Down Travel Speed and Sinking

Troubleshooting issues related to down travel speed and sinking.

Slack Rope Valve K

Down Leveling Adjustment 9

Overheating and System Leakage

Causes and Solutions for Power Unit Overheating

Identifying overheating causes and providing solutions.

Switch Distances for Landing and Stopping

Blain Hydraulics EV 100 Specifications

General IconGeneral
CategoryControl Unit
Flow RateUp to 100 L/min
Voltage24 VDC
Protection ClassIP65
Weight2.5 kg
MaterialAluminum
TypeHydraulic Control Unit