A064 Supply fan - Internal circuit high temperature Automatic reset Unit shutdown
A065 Supply fan - Motor high temperature Automatic reset Unit shutdown
A066 Supply fan - Low DC-link voltage Automatic reset Unit shutdown
A067 Supply fan - Limited mains power Automatic reset Unit shutdown
A068 Supply fan - Limited mains current Automatic reset Unit shutdown
A069 Supply fan - Brake mode Automatic reset Unit shutdown
A070 Supply fan - Cable break Automatic reset Unit shutdown
A071 Supply fan - Freeze protection Automatic reset Unit shutdown
A072 Supply fan - Heating: motor stop Automatic reset Unit shutdown
A073 Supply fan - Speed under limit Automatic reset Unit shutdown
A074 Supply fan - High DC-link voltage Automatic reset Unit shutdown
A075 Supply fan - High supply voltage Automatic reset Unit shutdown
A076 Supply fan - High line Impedance Automatic reset Unit shutdown
A077 Return fan - Offline Automatic reset Unit shutdown
A078 Return fan - Line fault Automatic reset Unit shutdown
A079 Return fan - Motor blocked Automatic reset Unit shutdown
A080 Return fan - Fire alarm Automatic reset Unit shutdown
A081 Return fan - Uin Low (FW 10) Reset by user Unit shutdown
A082 Return fan - Uin High (FW 10) Reset by user Unit shutdown
A083 Return fan - UZK low Reset by user Unit shutdown
A084 Return fan - UZK high Reset by user Unit shutdown
A085 Return fan - IGBT fault Reset by user Unit shutdown
A086 Return fan - Earth-GND fault Reset by user Unit shutdown
A087 Return fan - Peak current error Reset by user Unit shutdown
A088 Return fan - Hall sensor error Reset by user Unit shutdown
A089 Return fan - Offline Reset by user Unit shutdown
A090 Return fan - Phase failure Reset by user Unit shutdown
A091 Return fan - Motor blocked Reset by user Unit shutdown
A092 Return fan - Mains undervoltage Reset by user Unit shutdown
A093 Return fan - Mains overvoltage Reset by user Unit shutdown
A094 Return fan - DC-link overvoltage Reset by user Unit shutdown
A095 Return fan - DC-link undervoltage Reset by user Unit shutdown
A096 Return fan - Motor overheating Reset by user Unit shutdown
A097 Return fan - Internal circuit overheating Reset by user Unit shutdown
A098 Return fan - Outer stage overheating Reset by user Unit shutdown
A099 Return fan - Hall sensor error Reset by user Unit shutdown
A100 Return fan - Communication error Automatic reset Unit shutdown
A101 Return fan - Generic error Automatic reset Unit shutdown
A102 Return fan - Outer stage high temperature Automatic reset Unit shutdown
A103 Return fan - Internal circuit high temperature Automatic reset Unit shutdown
A104 Return fan - Motor high temperature Automatic reset Unit shutdown
A105 Return fan - DC-link low voltage Automatic reset Unit shutdown
A106 Return fan - Limited mains power Automatic reset Unit shutdown
A107 Return fan - Limited mains current Automatic reset Unit shutdown
A108 Return fan - Brake mode Automatic reset Unit shutdown
A109 Return fan - Cable break Automatic reset Unit shutdown
A110 Return fan - Freeze protection Automatic reset Unit shutdown
A111 Return fan - Heating: motor stop Automatic reset Unit shutdown
A112 Return fan - Speed under limit Automatic reset Unit shutdown
A113 Return fan - DC-voltage high Automatic reset Unit shutdown
A114 Return fan - High supply voltage Automatic reset Shutdown of VOC regulation