ART. 35/09175-00 PAGINA 4 DI 4
Activation
$IWHULQVWDOODWLRQWKH'HWHFWRUZLOOEHDFWLYDWHGXQGHUWKH
following conditions:
1. :KHQWKHGRRULVRSHQHGDQGPDJQHWPRYHVDZD\IURPWKH
PDLQERG\WKH5HHG6ZLWFKZLWKLQWKH'HWHFWRUZLOOEHDFWLYDWHG
2. :KHQWKH1RUPDO&ORVH1&GHYLFHFRQQHFWHGWR:LUH,QSXW
Terminal 1 is activated (opened).
3. :KHQWKHSXOOFRUGRIWKHUROOHUVKXWWHUFRQQHFWHGWR:LUH,QSXW
Terminal 2 is pulled down or retracted for set distance.
Please refer to Jumper Switch Setting section below for
setting roller shutter cord activation distance.
Tamper Switch
7KH 7DPSHU 6ZLWFK ZLOO EH FRPSUHVVHG DJDLQVW WKH PRXQWLQJ
surface when the Detector is properly installed.
7KHWDPSHUVZLWFKZLOOEHDFWLYDWHGZKHQWKH'HWHFWRULVUHPRYHG
from the mounting location, or when its cover is removed.
:KHQ WKH WDPSHU VZLWFK LV WULJJHUHG WKH 'HWHFWRU ZLOO VHQG D
signal to the Control Panel to notify the situation.
Test Mode
Press the Test Button to enter Test mode for 3 minutes.
Under Test mode, the LED indicator will light up every time the
Detector is activated.
LED Indicator
Off Normal Operation
On (2 seconds)
:KHQ7DPSHU6ZLWFKLVWULJJHUHG
-The Detector is activated (door opened/wired
device triggered/roller shutter activated) under
ORZEDWWHU\WDPSHUWULJJHUHGRU7HVWPRGH
Battery
7KH 'HWHFWRU XVHV RQH 9 $$ OLWKLXP EDWWHU\ DV LWV SRZHU
VRXUFH,WDOVRIHDWXUHVORZEDWWHU\GHWHFWLRQIXQFWLRQWRQRWLI\WKH
&RQWURO3DQHOZKHQEDWWHU\YROWDJHLVORZ
:KHQWKH'HWHFWRULVRQORZEDWWHU\IROORZWKHSURFHGXUHEHORZ
WRFKDQJHWKHEDWWHULHV
1. Remove the Detector from mounting location, open the
cover.
2. 5HPRYHWKHROGEDWWHU\
3. 3UHVVWKHOHDUQEXWWRQVHYHUDOWLPHVWRIXOO\GLVFKDUJH
4. ,QVHUWWKHQHZEDWWHULHVREVHUYLQJFRUUHFWSRODULW\
5. Replace the cover and re-install the Detector at mounting
location.
The jumper switches provides setting option for Door Contact
functions. Each jumper switch has 2 pins; the jumper setting is
GHWHUPLQHGE\KRZWKHMXPSHULVLQVWDOOHGRQWKHSLQV
-XPSHU2Q
The jumper link is
inserted connecting
the two pins
-XPSHU2II
if the jumper link
is removed or
parked on one pin.
The Door Contact has 5 jumper switches, marked JP1, JP3, JP5,
-3-3RQWKH3&%ERDUGIURPOHIWWRULJKW
-3±7HVW0RGH
This jumper is used to put the Door Contact into
permanent Test Mode.
21 The Door Contact is set to Test Mode permanently.
<RXGRQRWQHHGWRSUHVVWKH/HDUQ7HVWEXWWRQWR
enter Test Mode
2)) The Door Contact is set to Normal Mode.
<RXFDQVWLOOSUHVVWKH/HDUQ7HVWEXWWRQWRHQWHU7HVW
Mode temporarily for 3 minutes. (Factory Default)
-3±5HHG6ZLWFK
7KLVMXPSHULVXVHGWRHQDEOHRUGLVDEOHGWKH'RRU
Contact’s Reed Switch.
21 The Reed Switch is 'LVDEOHG. The Door Contact can
RQO\EHDFWLYDWHGE\WKH:LUH,QSXW7HUPLQDOV
2)) The Reed Switch is (QDEOHG. The Door Contact can
EHDFWLYDWHGE\ERWK5HHG6ZLWFKDQG:LUH,QSXW
Terminals. )DFWRU\'HIDXOW
-3-3-3±5ROOHU6KXWWHU3XOO&RUG
$FWLYDWLRQ'LVWDQFH
This jumper is used to set the distance the pull cord on the roller
VKXWWHUQHHGVWRWUDYHOEHIRUHWKH'RRU&RQWDFWLVDFWLYDWHG
7KHGLVWDQFHLVPHDVXUHGE\WKHQXPEHURISXOVHVLJQDOVHQWWR
:LUH,QSXW7HUPLQDOZKHQWKHSXOOFRUGLVSXOOHGRUUHWUDFWHG
2QO\RQHRIWKHMXPSHUVFDQEHWXUQHGRQDWDWLPH
-3 21 7KH 'RRU &RQWDFW ZLOO EH DFWLYDWHG DIWHU GHWHFWLQJ 
pulses from roller shutter within 10 seconds.
-3 21 7KH 'RRU &RQWDFW ZLOO EH DFWLYDWHG DIWHU GHWHFWLQJ 
pulses from roller shutter within 10 seconds.
)DFWRU\'HIDXOW
-3 21 7KH 'RRU &RQWDFW ZLOO EH DFWLYDWHG DIWHU GHWHFWLQJ 
pulses from roller shutter within 10 seconds.
Environmental Condition
-10°C to 40°C, relative humidity 85% non-condensing.
Radio
0+])0
User information ex art. 26 D. 49/2014
The symbol labelled on the appliance (Annex IX D. 49/2014) indicates that
WKHUXEELVKLVVXEMHFWWR´VHSDUDWHFROOHFWLRQµDQGLWKDVEHHQSODFHGRQWKH
Italian market after the December 31, 2010.
7KH XVHU PXVW WKHUHIRUH DVVLJQ RU KDYH FROOHFWHG WKH UXEELVK WR D
treatment facility according to indications by the local administration, or
KDQGLWRYHUWRWKHUHVHOOHULQH[FKDQJHIRUDQHTXLYDOHQWQHZSURGXFW7KH
separate collection of the rubbish and the subsequent treatment, recycling
and disposal operations encourage the production of appliances made
ZLWK UHF\FOHG PDWHULDOV DQG UHGXFH QHJDWLYH HͿHFWV RQ KHDOWK DQG WKH
HQYLURQPHQWFDXVHGE\LPSURSHUWUHDWPHQWRIUXEELVK
,QWKHFDVHRIYHU\VPDOO:(((QRH[WHUQDOGLPHQVLRQPRUHWKDQFP
the user is eligible to get free of charge assignation to retail shops with
sales areas relating to EEE of at least 400 m².
',675,%87('%<
ELCART DISTRIBUTION SPA
Via Michelangelo Buonarroti, 46
20093 COLOGNO MONZESE (MI)
ITALY
www.elcart.com - info@elcart.it
Operation
Jumper Switch Setting
6SHFL¿FDWLRQ

Other manuals for Blaupunkt DC-S3

Related product manuals