10.8 Set height limit
This function is used to limit the lifting height if it is to be reached several times during the
vehicle repair. The function is only active in group mode. With the dissolution of the group,
the limit value is deleted.
1. Raise the vehicle to the desired height.
2. Briefly press the altitude limit button until the display [2] flashes yellow. The altitude
limit has been saved.
3. When the vehicle reaches the limit value during lifting, the movement stops
automatically and the display [2] flashes.
10.9 Charge batteries
DANGER
Danger of death and injury from explosive gases, which may result in burns and
permanent loss of vision.
Only charge the battery in well-ventilated areas.
Never use damaged charging cables.
WARNING
Risk of electric shock / short circuit due to live parts.
Only connect the device to a properly installed power outlet
The local mains voltage must correspond to the technical data of the
lifting unit.
1. Switch off the main switch.
2. Insert the charging cable into the charging socket
[2].
3. Plug the charging cable into the socket.
4. Charge level is displayed in the control panel.
5. During charging the display [1] shows red,
switching to green, the charging is finished.
6. The battery display indicates the current state of
charge of the battery.