HydroLift
Error messages
2. Key for slow lowering
(Error? Check / replace
small lowering valve and
wiring).
3. Put in pawl (Error? Check
/ replace large lowering
valve and wiring).
4. Lowering key (Error?
Check / replace solenoid
valve and pawl wiring).
E8
Different software
versions
Software version is
different on activated lifting
units.
Update software on all lifting
units.
E9
Defective key
Defective key detected
when switching on.
Key was pressed for more
than 2.5 minutes.
Replace defective key.
E10
Connection errors
No connection between
motherboard and input
board.
Check cables between
boards and replace if
necessary.
Check circuit boards.
E11
Battery voltage
Battery voltage too low.
Charge battery.