12 Error messages
The processor has
detected an error.
Acknowledge error message
with key "X".
If the problem persists,
contact Customer Service.
Lifting unit from the active
group has been switched
off at the main switch.
Initially, error CL is
displayed.
When switching on again,
the remaining lifting units
show fault E1.
A second system sends on
the same frequency.
Acknowledge error message
on all lifting units with key
"X".
Reconfigure wheel gripper.
Check transmission
frequency of other radio
equipment in the area.
Wrong coupling of the
wheel gripper
There is an invalid
configuration.
Acknowledge the error
message with the "X" key.
Aerial cable without
contact.
Aerial defective.
Radio modem defective.
Check aerial and aerial
cable.
Check radio modem and
replace if necessary.
Nominal load exceeded.
Unevenly distributed loads.
Battery charge too low.
Security notch blocked.
Error in the hydraulic
system.
Correct difference in height
manually.
Check nominal load and load
distribution.
Charge batteries.
Check safety notches.
Power supply interrupted.
Measuring signal of a
sensor outside the
permitted range.
Manually lower lifting units.
Replace sensor.
Short circuit switching
relay 1 on the motor.
Check wiring of switching
relay 1. Replace switching
relay 1.
Short circuit switching
relay 2 on the motor.
Check wiring of switching
relay 2. Replace switching
relay 2.
Short circuit in main board.
Group message for
overload on a switching
relay.
Faulty component search.
1. Up-key (error?
Check/replace motor
protection and wiring).