BC14G
1-1
INSTALLATION SPECIFICATIONS/INFORMATION
Before starting to troubleshoot an oven, verify the
oven has been installed correctly. The installation of
the electric and gas connections must be performed
by a qualified installer only. The installation must conĆ
form to all local and national installation standards. A
hood system is required with the BC14G.
MAXIMUM SHELF LOADING
BC14G 100 lbs (45.5 Kg)
TABLE 1
PLUMBING SPECIFICATIONS - BC14G/AA
Water
Water Pressure 30 PSI (207 kPa) minimum
50 PSI (345 kPa) maximum
Water Connection 3/4" Hose Hot and Cold Water
Water Regulator Setting Preset to 20 PSI (138 kPa)
Drainage Atmospheric Vented Drain
Drain Connection 2.00" (50.8mm) Copper
Avg Water Drain Temp. Approximately 160_F (71_C)
TABLE 2
PLUMBING SPECIFICATIONS - BC14GDS/AA
Water
Water Pressure 30 PSI (207 kPa) minimum
50 PSI (345 kPa) maximum
Water Connection 3/4" Hose Cold Water
Water Regulator Setting Preset to 20 PSI (138 kPa)
Drainage Atmospheric Vented Drain
Drain Connection 2.00" (50.8mm) Copper
Avg Water Drain Temp. Approximately 160_F (71_C)
NOTE: For steam requirements see page 1-5 STEAM CONNECTION for the BC14GDS.