Cooking zone specific errors
Priority Display Description System
1 E5 LIN Bus communication error. Most
probably diagnosed by the Touch
Control unit and indicated as Er47
Induction
2 E5 Defective controller flash. Incorrect
checking total
Induction
3 E5 Wrong programming options Induction
4 E5 Incorrect EEPROM checking total Induction
5 E5 Unclear EEPROM data Induction
6 U400 Overvoltage 400V (becomes general error
with Touch Control as
soon as indicated by at least one induction
cooking zone)
Induction
7 E5 Error mains voltage signal Induction
8 E7 Sub LIN error between filter and power
board
Induction
9 E6 5V short circuit with power board Induction
10 E6 12V too low for power board Induction
11 E6 Defective temperature sensor on cooling
element
Induction
12 E6 Faulty mains hold pulse Induction
13 E9 Defective coil detector Induction
14 E2 Overheated coil detector (diagnosed by
induction)
Induction
15 „Blitz“ Permanent operation (minim. 10 sec) upon
switching a cooking zone
off
all
16 „Blitz“ Permanent operation (minim. 10 sec)
without switching a
cooking zone off
all
13