E2 Overheating
E5 Exchange filter board
E6 Exchange power board
E7 Unknown error, cannot be clearly identified
E9 Exchange temperature sensor
4 Technical data
Rated voltage and current
nominal voltage: 220-240 V
nominal frequency: 50-60 Hz
The power of a power board is limited to 3700 W.
Use only rubber cable type H05VV-F; the cross-setion on the wires must be
3x1.5mm.
Stand-by consumption of the generator
Max. 0,6 W (not including user interface).
Nominal power and diameters of coils
Diameter Nominal power Boost power
Ø 145 mm
1400 W 1800 W
Ø 210 mm
2300 W 3200 W
diameter nominal power boost power