Test process for Key cant work
NO
NO
YES
NO
Key cant work
All key cant
work
Single key cant
work
Some of key cant work
(e.g: 1/2/3, regular problem)
Upgrade software
to check if can
solve this problem
Visual check if any corrosion or short
circuit, and use multimeter to check
if any short circuit for single key
Clean the place
which is corrosion
or short circuit
Re-solder or
change CPU
U101 MT6250
Clean it
Use multimeter to check if
the voltage is 0.7V or not