34
Check charger and cable without
problem, or change good one
Connect the charger without
battery put in, check if the voltage
of positive pole is around 3.6V.
Check charge protective tube be
normal.
Replace or re-solder CPU MT6250
No charge
Does not charge no charge
in
Change battery
Re-flash SW
Resolved
Check if I/O connector
works normal
Replace
or
re-solder
it
NO
NO
YES
YES
NO
YES
YES
YES
YES