Loading...
No photograph
Start
Update software or
resetting factory
YES
Over
No
Check the camera is
ok or not
No
Check the
Connector no
damage
YES
Replace a
new one
YES
Change the
connector
Check Power
AVDD/DVDD if
unnormal
YES
Change U0401
No
Replace Main PCBA Check U1001
YES
Change U1001