Product User Manual
52V Series / Single unit models
UDS House Section 1 Office: +27 21 205 2000
22 Gardner Williams Ave Technical Support: support@bluenova.co.za
Paardevlei, 7130 Website: www.bluenova.co.za
A. INTRODUCTION
Congratulations on purchasing a high quality BlueNova® product.
This document covers product assembly & installation, troubleshooting, safety & maintenance
instructions, storage guidelines as well as emergency & first aid procedures.
Please do not discard this document as it contains valuable information that might have to be
referenced at a later stage.
Should you have any queries, kindly contact BlueNova® Technical Support:
Office: +27 21 205 2000 E-mail: support@bluenova.co.za
B. COMPONENT DIAGRAM
A BlueNova® single unit battery requires no assembly before installation:
C. INSTALLATION
The following highlighted values have to be set on the inverter/charger. Note: Disable equalisation.
Parameter
Cell V
Value
12V Eq
Comment
V high cut-off
4.00 V
64.0 V
16.0 V
Over voltage. Battery will isolate automatically.
V high set
3.51 V
56.2 V
14.1 V
100% SoC. Constant voltage set point. Charger must
pause until V float is reached.
V bypass
3.50 V
56.0 V
14.0 V
Internal set to battery for balancing.
V float
3.40 V
54.4 V
13.6 V
Charger must reconnect when this voltage is reached.
V reconnect
3.00 V
48.0 V
12.0 V
Mains or generator must reconnect to charge batteries.
V low set
2.90 V
46.4 V
11.6 V
Inverter must switch off the load.
V low cut-off
2.80 V
44.8 V
11.2 V
Under voltage. Battery will isolate automatically.