SOLAR BOOST™ 50
50AMP 12/24VDC MAXIMUM POWER POINT TRACKING
PHOTOVOLTAIC CHARGE CONTROLLER
INSTALLATION AND OPERATION
MANUAL
THIS MANUAL INCLUDES IMPORTANT SAFETY INSTRUCTIONS FOR MODELS
SB50L, SB50DL, SB50RD25
SAVE THESE INSTRUCTIONS
CE MANUEL CONTIENT D’INSTRUCTIONS IMPORTANTES POUR LES MODELES
SB50L, SB50DL, SB50RD25
PRIERE DE SAUVEGARDER CES INSTRUCTIONS
DIESES HANDBUCH ENTHÄLT WICHTIGE HINWEISE FÜR DIE MODELLE
SB50L, SB50DL, SB50RD25
BITTE BEHALTEN SIE DIESE HINWEISE
ESTE MANUAL INCLUYE INSTRUCCIONES DE SEGURIDAD IMPORTANTES PARA
LOS MODELOS
SB50L, SB50DL, SB50RD25
CONSERVE ESTAS INSTRUCCIONES
COVERED UNDER ONE OR MORE OF THE FOLLOWING US PATENTS
6,111,391 6,204,645
© Blue Sky Energy, Inc. 2003 430-0015 D
2003167
CONFORMS TO
UL STD. 1741
CERTIFIED TO
CAN/CSA STD. E335-1/2E
This device complies with part 15 of the
FCC rules. Operation is subject to the
following two conditions: 1) This device
may not cause harmful interference, and 2)
This device must accept any interference
received, including interference that may
cause undesired operations.
CONFORMS TO
EN 50081-1
EN 50082-1
EN 60335-1

Questions and Answers

  • S
    shannonbryanAug 16, 2025
    Why is the charge current lower than expected on my Blue Sky Energy SOLAR BOOST 50?
    • J
      Joshua AllenAug 17, 2025
      A lower than expected charge current in your Blue Sky Energy Inverter, along with low PV current, can be due to several reasons. The battery might be highly charged, reducing the current during Acceptance or Float stages. Worn out PV modules or low insolation (atmospheric haze, dirty PVs, low sun) can also cause this. Ensure PV- and BAT- are separate. Verify dip switch #5, proper MPPT setup, and MPPT trim.
  • E
    Elizabeth RamseyAug 19, 2025
    What to do if Blue Sky Energy SOLAR BOOST 50 Inverter display is OK but system won't turn on?
    • H
      Heather CrawfordAug 19, 2025
      If the display is OK but your Blue Sky Energy Inverter system won't turn on and the charge status LED is off, check your PV connections. Ensure they're properly connected and not in reverse polarity, and that PV- isn't connected to BAT-. The PV needs to supply at least 0.15A at 2.5V more than the battery voltage to start charging. Reverse polarity PV will heat the heat sink and show negative PV current if the battery is connected. PV- and BAT- must be separate for proper operation.
  • C
    cherylgardnerAug 22, 2025
    Why is the MPPT current boost less than expected on my Blue Sky Energy Inverter?
    • J
      James MillsAug 22, 2025
      If the MPPT current boost is less than expected on your Blue Sky Energy Inverter, it could be because the PV maximum power voltage (VMP) isn't much higher than the battery voltage. Hot PVs or improper MPPT setup can also be factors. PVs with a VMP ? 17V work best. Check for excessive PV wiring voltage drop, and verify dip switch #5 along with proper MPPT setup and trim. The MPPT LED being off indicates that extra power isn't available from the PV array.
  • H
    Heather MurphyAug 25, 2025
    Why is the charge status LED on in Bulk but no output charge current on my Blue Sky Energy SOLAR BOOST 50?
    • A
      Angela GibsonAug 26, 2025
      If the charge status LED is on in Bulk, but there's no output charge current from your Blue Sky Energy Inverter, double-check dip switches #1-5 for the correct system voltage. Also, ensure the temperature sensor is connected with the correct polarity or replace the sensor. Proper temp sensor terminal voltage when connected is 2.98V at 25°C, changing at +10mV/°C.
  • C
    Christopher ThomasAug 27, 2025
    Why won't my Blue Sky Energy Inverter switch between Acceptance & Float correctly?
    • L
      Lance AcevedoAug 27, 2025
      If your Blue Sky Energy Inverter system seems OK but isn't correctly switching between Acceptance & Float, double-check dip switches #10 & 11. The battery might be too discharged, PV power might be too low, or loads might be too high to reach the desired charge voltage. The system won't switch from Float to Acceptance until the charge current is greater than the Float Transition Current setting. If using an external shunt, verify the charge current polarity.
  • M
    Michael JonesAug 30, 2025
    Why is the charge status LED on in Float or Accept. but no output charge current on my Blue Sky Energy SOLAR BOOST 50 Inverter?
    • A
      Amber ThomasAug 30, 2025
      If the charge status LED is on in Float or Accept. but there's no output charge current from your Blue Sky Energy Inverter, it's likely normal operation due to a high battery voltage, possibly from other charging systems. Double-check dip switches #1-5. If temp compensation is enabled without a sensor or the sensor failed, disable temp compensation or replace the sensor. Ensure the battery voltage is at least 9V in a 12V system or 18V in a 24V system.
  • J
    John WallerSep 2, 2025
    Why is the charge status LED on in Bulk with no output and relays clicking on my Blue Sky Energy Inverter?
    • S
      Susan WilliamsSep 2, 2025
      If the charge status LED is on in Bulk, but there's no output charge current and the relays click on and off on your Blue Sky Energy Inverter, double-check dip switches #1 & 2 for the correct system voltage. Also, verify that PV- and BAT- are not connected together via earth GND or any other connection.
  • L
    Louis BenderSep 4, 2025
    What does it mean when the charge status LED blinks rapidly on my Blue Sky Energy SOLAR BOOST 50 Inverter?
    • A
      Amy LeeSep 4, 2025
      If the charge status LED blinks rapidly and the charge voltage may be high on your Blue Sky Energy Inverter, the system is likely in equalize mode. To disable equalize, press the equalize pushbutton.
  • J
    Jacqueline BeasleySep 7, 2025
    Why does my Blue Sky Energy SOLAR BOOST 50 Inverter charge turn off at high temperatures?
    • T
      Thomas MirandaSep 7, 2025
      If your Blue Sky Energy Inverter's charge turns off at high ambient temperatures, it's likely shutting down temporarily due to a high heat sink temperature. Improve ventilation or reduce PV power to prevent this. Ensuring sufficient ventilation can enhance reliability.
  • F
    Frances RodriguezSep 10, 2025
    Why are the relays clicking on/off when the charge status LED is on in Float or Accept. on my Blue Sky Energy Inverter?
    • S
      stephanie34Sep 10, 2025
      If the charge status LED is on in Float or Accept., and the relays click on and off on your Blue Sky Energy Inverter, the charge current might be very low, and the system is on the edge of being able to stay on. If the charge current is very low (?0.1 – 0.2A) because the battery voltage is at the setpoint, the relays may switch on/off. This is normal and won't cause any harm. The symptom will disappear with a slight increase or decrease in battery load.

Summary

Safety and Preliminary Checks

Important Safety Instructions

Essential safety guidelines, personal precautions, and installation safety for safe operation.

Preparing to Charge

Procedures for preparing batteries before initiating the charging process.

Product Description and Operation

Product Description and Options

Overview of the Solar Boost 50, its technology, part numbers, and available options.

Charge Status Indicators and Modes

Explains LED indicators, three-stage control (Bulk, Acceptance, Float) and two-stage control.

Advanced Charging Features

Details on equalization, disabling equalization, and temperature compensation.

MPPT Technology and Performance

Explanation of MPPT operation, current boost, and typical performance.

Installation and Setup Procedures

Installation Safety and Protection

Warnings, over-voltage/reverse polarity protection, and NEC compliance for safe installation.

Electrostatic Handling & PV Current Limits

Procedures to prevent static damage and requirements for PV short circuit current.

Unit Setup and Configuration

Details on dip switch settings, system voltage, charge mode, and factory defaults.

Temperature Compensation & Shunt Setup

How to enable temperature compensation and set up current measurement shunts.

Float Transition & MPPT Settings

Setting the float transition current and maximum power voltage for MPPT.

Acceptance;Float Voltage & Mounting

Adjusting charge voltages and instructions for mounting the unit.

Wiring and Conduit Requirements

Guidance on battery/PV wiring, conductor sizing, and conduit requirements.

Optional Features and Troubleshooting

Optional Components and Displays

Information on external current shunts and digital displays, including wiring.

Alternative Power Sources

Guidelines for operating the unit with power sources other than PV modules.

Troubleshooting Guide

Diagnosing and resolving common symptoms and probable causes for unit malfunction.

Specifications and Warranty

Technical Specifications

Detailed electrical and physical specifications for the Solar Boost 50.

Three-Year Limited Warranty

Terms and conditions of the manufacturer's limited warranty for the product.

Blue Sky Energy SOLAR BOOST 50 Specifications

Power IconPower
output current rating50A
system voltage12/24VDC nominal
max PV open circuit voltage57VDC
max battery voltage57VDC
output current limit50±2A
Meter Specifications IconMeter Specifications
volt meter full scale range60.0V
volt meter accuracy±0.3% full-scale
current meter full scale range±60A
current meter accuracy±0.5% full-scale
Temperature and Efficiency IconTemperature and Efficiency
storage temperature range-40 to +85°C
specified temperature range0 to +40°C
power conversion efficiency97% typical @ 40A
Dimensions IconDimensions
cabinet dimensions10”Hx8¾”Wx3½”D
remote display module14½”Hx4½”Wx1¾”D