OPERATION USING BOTTLE GAS (cont.)
8. Open the gas valve of the gas cylinder; press the gas valve knob in the panel, wait
approximately 15 seconds, turn the pressed knob in the direction of the arrow,
a click of the igniter can be heard and the gas flame is ignited. Hold the knob
pressed in this position so that the flame remains burning. It might be possible
that this operation has to be repeated a couple of times, especially if the appliance
has not been used for a long time or if the gas cylinder has been changed. There
can be an air in the system, which has to be forced out. It is necessary to check
that the pilot is lit by looking through the orifice at the top of the unit or through
the hole at the back near the burner. If the flame fails to light, wait at least a
minute before trying again.
9. To disconnect the fridge running on gas: close the valve of the gas cylinder and
then turn the gas valve knob in the panel to position ‘press’.
10. When using the gas as a power source, there is no thermostatically temperature
controller (i.e. you cannot increase or decrease the temperature inside the fridge).
The cooling performance of the fridge using gas energy source would be as
follows: at 25~32° ambient, the inside temperature of the fridge would be around
18~22° below ambient.