TECHNICAL DATA
Item No.
Net capacity
Refrigerant
AC supply
DC supply
Climate class
Isolation
Gas category
Gas type
Gas pressure
Heat input
Gas consumption
Destination country
Gas cylinder
Gas hose
Gas regulator
This appliance belongs to type A
11
Read manufacturer’s instructions before use - this appliance shall be installed
according to the rules in force.
To be used only in well-ventilated area, above ground and protected from rain.
XC-43G, FA50G
43L
Ammonia- NH3, 85g
230V/50Hz, 90W, 0.39A
12V, 90W, 7.5A
N, SN
Cyclopentane
I3+(28~30/ 37) I3B/P(30) I3B/P(37) I3B/P(50)
G30 (Butane), G31 G30 (Butane), G31 (Propane) and their
(Propane) mixtures
G30 (Butane) at 28-30 mbar 37 mbar 50 mbar
(28-30) mbar / G31
(Propane) at 37
mbar
150W 180W 180W
11 g/h 13 g/h 13 g/h
BE, FR, IT, LU, IE, LU, NL, DK, FI, PL DE, AT,
GB, PT, ES, CY, CZ SE, CY, CZ, EE CH, LU,
LT, SK, CH, SI, LV LT, MT, SK, SI, SK
BG, IS, NO, TR,
HR, RO, IT, HU
LV
Standard gas cylinder with maximum weight not exceeding
15 kg (Maximum Dia. 320mm, Maximum height 550mm /
below the gas connection). The cylinder shall comply with
local code. The cylinder should be firmly fixed. Do not use
or store near flammable or explosive products.
Certified gas hose according to applicable EN-standard and
comply with local code (max 1.5m / 1.2m in Finland).
NB/ It is necessary to change the hose when national
conditions require it.
Certified regulator according to EN 12864