Controlling Room Scheduler LED’s
These Instructions only apply to the BSBI Room Scheduler Screen.
The Room Scheduler unit comes with four LED strips on the sides of the screen,
which can display in green or red. These LED’s can be controlled via the GPIO
commands in BrightAuthor.
To enable LED control
Open a BrightSign presentation in BrightAuthor and select File > Presentation
Settings. Navigate to the I/O tab. Select “Output” next to GPIO 2 and 3. The lights will
be turned off by default when running this presentation.
To Activate LED’s within a Presentation
Double click the state or event where you want the LED to activate. Select the
Advanced tab from the window that appears. Click the + button to add a new
command.
To Display Green LED’s, set this command to “GPIO > On > 3”
To Display Red LED’s, set this command to “GPIO > On > 2”
To Display Yellow LED’s, set both commands
To Turn Off LEDs, set any On’s to Off.