6.3 - Function errors
6 - Troubleshooting
Error Cause Solution Comment
Motor does not run Assembly machine is not connected to
the power supply
Connect assembly machine to the power
supply
none
Building fuse has failed Reset fuse or replace none
Swing arm is swivelled down Swivel up swing arm See point 2.1.12
Check mains voltage and compare with
motor data. Have checked by authorised
electrician
Assembly machine connected to the
wrong voltage
See electrical dia-
gram
Motor defective Have motor replaced by an authorised
electrician
none
Motor overheats
Assembly machine connected to the
wrong voltage
Check mains voltage and compare with
motor data. Have checked by authorised
electrician
See electrical dia-
gram
Drilling in hard wood with too high a
speed
Pull handle down slower none
Motor hood is dirty or covered by some-
thing
Remove objects and chips in the area of the
motor hood
none
Gearbox defective Support, spindles or gears are damaged Replace gearbox none