5
Theapplianceshallbe
installedinaccordancewith
nationalwiringregulations;
Themaximumrefrigerant
chargeamount:45g;
Anunventilatedareawhere
theapplianceusingammable
refrigerantsisinstalledshall
besoconstructedthatshould
anyrefrigerantleak,itwillnot
stagnatesoastocreateare
orexplosionhazard.
Theapplianceshallbestored
soastopreventmechanical
damagefromoccurring.
Checkthatcablingwillnotbe
subjecttowear,corrosion,
excessivepressure,vibration,
sharpedgesoranyother
adverseenvironmental
effects.Thecheckshall
alsotakeintoaccountthe
effectsofagingorcontinual
vibrationfromsourcessuch
ascompressorsorfans.
Thefollowingleakdetection
methodsaredeemed
acceptableforsystems
containingammable
refrigerants.
Electronicleakdetectorsshall
beusedtodetectammable
refrigerants,butthesensitivity
maynotbeadequate,ormay
needre-calibration.(Detection
equipmentshallbecalibrated
inarefrigerant-freearea.)
Ensurethatthedetectoris
notapotentialsourceof
ignitionandissuitableforthe
refrigerantused.
Leakdetectionequipment
shallbesetatapercentage
oftheLFLoftherefrigerant
andshallbecalibratedtothe
refrigerantemployedandthe
appropriatepercentageofgas
(25%maximum)isconrmed.
Leakdetectionuidsare
suitableforusewithmost
refrigeransbuttheuseof
detergentscontainingchlorine
shallbeavoidedasthe
chlorinemayreactwiththe
refrigerantandcorrodethe
copperpipe-work.
Ifaleakissuspected,all
nakedamesshallbe
removed/extinguished.
Ifaleakageofrefrigerantis
foundwhichrequiresbrazing,
alloftherefrigerantshallbe
recoveredfromthesystem,or
isolated(bymeansofshutoff
valves)inapartofthesystem
remotefromtheleak.Oxygen
freenitrogen(OFN)shallthen
bepurgedthroughthesystem
bothbeforeandduringthe
brazingprocess.
Beforecarryingoutthis
procedure,itisessential
thatthetechnicianis
completelyfamiliarwiththe
equipmentandallitsdetail.
Itisrecommendedgood
practicethatallrefrigerants
arerecoveredsafely.Prior
5063022047595_MNL_IN_V03.indb 55063022047595_MNL_IN_V03.indb 5 30/11/2022 10:08 AM30/11/2022 10:08 AM