Secure oxygen monitor sensor for cylinders 1 to 3 with special tool 11 7 030.
Fig. 407: Installing Oxygen Monitor Sensor
Courtesy of BMW OF NORTH AMERICA, INC.
Secure oxygen monitor sensor for cylinders 4 to 6 with special tool 11 7 020.
Tightening torque 11 78 1AZ. Refer to ENGINE - TIGHTENING TORQUES .
Cover oxygen monitor sensors when applying underseal.
Pay attention to cable routing of oxygen monitor sensors.
POSITIVE CRANKCASE VENTILATION/OIL SEPARATOR
2006 BMW X5 30i
2004-2006 ENGINE Engine Mechanical - Repair Instructions - X3 & X5 (M54)