Specification
CX6- Programmable Heater Controller
Programming
7 Day or 5/2 Day
Power Supply
Powered from any SystemX heater through network cable
(battery back-up)
Temperature Sensor Type
±1°C at 20°C
Temperature Adjustment Range
5°C to 30°C
Plastic
Thermoplastic, flame retardant
Number of Programs Per Day
2, 4 or 6 (Default: 2)
Factory Pre-Set Programs per Day
2, 4 or 6 (Default: 2)
BST/GMT Time Change
Automatic
Tamper Resistant
Various screen / button locks if required to stop misuse
Remote Temperature Sensor
Available as optional extra (Part No CXS)
Dimensions
120mm (L) x 80mm (W) x 35mm (D)
Protection Rating
IP30
Complies with:
EN60730-1 EN 60730-2.7, EMC Directive 2014/30/EU,
LVD Directive 2014/35/EU
Special Features
1) Adaptive Start
The Adaptive Start function adjusts the starting time for the heating according to the temperature measured
within the room / building. Instead of setting an arbitrary time for the heating to come on, you programme the
time that the room / building should be at the desired temperature. Up to 10% of energy costs can be saved,
as the warm up time is automatically reduced according to the ambient temperature. Many users set their
heating to start a couple of hours before use to warm up the room / building. With the Adaptive Start function
you don’t need to do this. The actual start time is automatically delayed or advanced to ensure your room /
building reaches the set temperature by the programmed time. The Adaptive Start function is designed to work
with well insulated rooms / buildings that do not have a throughput of people and doors or windows being
opened regularly before the heating period.
2) Logical Heat Controller
Only works when Full Power in Settings is set to “YES”. Reduces the overrun of temperature by turning down
the power on each heater as it gets close to the temperature set point. You should not notice the effect on the
temperature but you should see a slight reduction in your energy bill.
3) Various screen locks
To stop the problem with passers by pressing buttons and adjusting the thermostat there are various ways of
locking the screen and disabling the buttons from working.