67 S130 Operation & Maintenance Manual
HYDRAULIC CONTROLS (CONT’D)
Secondary Front Auxiliary Hydraulics Operation
This machine can be equipped with Secondary Front
Auxiliary Hydraulics.
Figure 67
The secondary front auxiliary quick couplers (Item 1)
[Figure 67] are available as a Field Installed Accessory.
These are used when there is a need for additional
auxiliary hydraulics. (EXAMPLE: Side shift on the
Planer.)
Connect the attachment to the secondary front auxiliary
hydraulics (Item 1) [Figure 67].
Figure 68
Press the auxiliary hydraulics button (Item 1) [Figure 68]
once to engage auxiliary hydraulics.
The light (Item 2) [Figure 68] will be ON.
Standard, ACS and AHC (If Equipped)
Figure 69
SJC (If Equipped)
Figure 70
Push switch (Item 1) [Figure 69] or [Figure 70] to the
right or left to change fluid flow direction. (EXAMPLE:
Side shift on the Planer.)
NOTE: The secondary front auxiliary hydraulics and
the rear auxiliary hydraulics operate from the
same auxiliary section of the control valve. To
operate an attachment with secondary front
auxiliary hydraulics, you must disconnect any
attachment connected to the rear auxiliary
hydraulic quick couplers.
To disengage, press the auxiliary hydraulics button (Item
1) [Figure 68] again.
The light (Item 2) [Figure 68] will be OFF.
NOTE: When the operator is seated and raises the
seat bar, the Auxiliary Hydraulic System
(Front and Rear) will deactivate.
P16291A
1
SECONDARY COUPLERS
P-76460C
1
2
1
P16537B
P-31833A
1
P-27820A
P-24802A