66 S130 Operation & Maintenance Manual
HYDRAULIC CONTROLS (CONT’D)
FRONT Auxiliary Hydraulics Operation
(CONTINUOUS FLOW)
Standard, ACS and AHC (If Equipped)
Figure 63
SJC (If Equipped)
Figure 64
Press the front switch (Item 2) [Figure 63] and [Figure
64] to give the front quick couplers a constant flow of fluid
with the female coupler being pressurised. (EXAMPLE:
Operate a backhoe.)
REVERSE CONTINUOUS FLOW - To set reverse flow
(male coupler pressurised), engage auxiliary hydraulics,
then, while holding the auxiliary switch (Item 1) to the left,
press the front switch (Item 2) [Figure 63] and [Figure
64].
NOTE: Reverse flow can cause damage to some
attachments. Use reverse flow with your
attachment only if approved. See your
attachment Operation & Maintenance Manual
for detailed information.
To release from continuous operation, press the front
switch (Item 2) [Figure 63] or [Figure 64] a second time.
NOTE: When the operator is seated and raises the
seat bar, the Auxiliary Hydraulic System
(Front and Rear) will deactivate.
REAR Auxiliary Hydraulics Operation
This machine can be equipped with Rear Auxiliary
Hydraulics.
Figure 65
Figure 66
The switches on the left hand lever or joystick control the
rear auxiliary hydraulics.
Press the auxiliary hydraulics button (Item 1) [Figure 65]
once to engage auxiliary hydraulics.
The light (Item 2) [Figure 65] will be ON.
Push the switch (Item 3) [Figure 63] or [Figure 64] to the
right or left to change the fluid flow direction to rear quick
couplers [Figure 66]. (EXAMPLE: Raise and lower rear
stabilizers.)
To disengage, press the auxiliary hydraulics button (Item
1) [Figure 65] again.
The light (Item 2) [Figure 65] will be OFF.
NOTE: When the operator is seated and raises the
seat bar, the Auxiliary Hydraulic System
(Front and Rear) will deactivate.