206 S450 Operation & Maintenance Manual
DIAGNOSTIC SERVICE CODES (CONT'D)
Service Codes List (Cont’d)
CODE DESCRIPTION CODE DESCRIPTION
M2303 Starter relay error OFF M4902 Rear light relay error ON
M2402 Fuel pull relay error ON M4903 Rear light relay error OFF
M2403 Fuel pull relay error OFF M5002 Front light output error ON
M2502 Traction pull relay error ON M5003 Front light output error OFF
M2503 Traction pull relay error OFF M5007 Front light output open circuit
M2602 Glow plug relay error ON M5028 Front light output failure
M2603 Glow plug relay error OFF M5102 Rear light output error ON
M2721 Throttle primary sensor out of range high M5103 Rear light output error OFF
M2722 Throttle primary sensor out of range low M5107 Rear light output open circuit
M2821 Throttle secondary sensor out of range high M5128 Rear light output failure
M2822 Throttle secondary sensor out of range low M5202 Press to operate button error ON
M3028 Controller memory failure M5221 Press to operate button out of range high
M3128 Interrupted power failure M5222 Press to operate button out of range low
M3204
ACS (AHC) no communication to Bobcat
controller
M5305 Press to operate light short to battery
M3304 Deluxe panel no communication M5306 Press to operate light short to earth
M3404 Deluxe panel in error M5405 Tilt spool lock short to battery
M3505 Hydraulic fan short to battery M5406 Tilt spool lock short to earth
M3506 Hydraulic fan short to earth M5407 Tilt spool lock open circuit
M3507 Hydraulic fan open circuit M5432 Tilt spool lock overcurrent
M3532 Hydraulic fan overcurrent M5810 Fuel temperature too high
M3705 Two-speed second output short to battery M5811 Fuel temperature extremely high
M3706 Two-speed second output short to earth M5815 Fuel temperature in shutdown
M3707 Two-speed second output open circuit M5826 Fuel temperature pre-shutdown
M3732 Two-speed second output overcurrent M5902 DPF regeneration switch error ON
M3805 Auxiliary hydraulic lock short to battery M6002 DPF inhibit regeneration switch error ON
M3806 Auxiliary hydraulic lock short to earth M6102 Remote parked regeneration switch error ON
M3807 Auxiliary hydraulic lock open circuit M6402 Switched power relay error ON
M3832 Auxiliary hydraulic lock overcurrent M6403 Switched power relay error OFF
M4028 Wrong ECU detected M6505 ECU power short to battery
M4109 Alternator voltage too low M6506 ECU power short to earth
M4110 Alternator voltage high M6507 ECU power open circuit
M4111 Alternator voltage extremely high M6604 ECU no communication
M4304 Keyless panel no communication M6702 HVAC output error ON
M4404 Auxiliary no communication M6703 HVAC output error OFF
M4510 Water in fuel sensor too high M6707 HVAC output open circuit
M4511 Water in fuel sensor extremely high M6728 HVAC output failure
M4521 Water in fuel sensor out of range high M6802 HVAC relay error ON
M4522 Water in fuel sensor out of range low M6803 HVAC relay error OFF
M4621 5 volt sensor supply out of range high M7002 Switched power output error ON
M4622 5 volt sensor supply out of range low M7003 Switched power output error OFF
M4721 8 volt sensor supply out of range high M7007 Switched power output open circuit
M4722 8 volt sensor supply out of range low M7028 Switched power output failure
M4802 Front light relay error ON M7304 Remote control no communication
M4803 Front light relay error OFF M7316 Remote control no communication to transmitter