71 S650 Operation & Maintenance Manual
SPEED MANAGEMENT
Speed Management is available on SJC equipped
machines.
Operation
Speed Management allows the loader to be maneuvered
at a slower travel speed, even during maximum
movement of the joystick(s).
This feature can be useful when installing attachments,
loading or unloading, and certain applications.
(EXAMPLES: Landscaping, tilling, trenching)
NOTE: Two-Speed Loaders Only - You must be in low
range speed to engage Speed Management.
Figure 61
Press the button (Item 1) [Figure 61] on the left joystick
once to engage Speed Management.
Figure 62
The Speed Management icon (Item 1) [Figure 62] will
appear in the display and remain on until the Speed
Management button is pressed again or the machine is
turned off.
When Speed Management is engaged, the machine will
travel at the factory default setting of 57% of Standard
Travel Speed and the percentage [SPD 57] will appear in
the display (Item 2) [Figure 62].
NOTE: The factory default setting can be changed by
the operator. (See Changing The Factory
Default Setting on Page 72.)
While Speed Management is engaged, press the top of
the Speed Control switch (Item 2) [Figure 61] to increase
the speed up to 99% [SPD 99] or the bottom of the switch
(Item 3) [Figure 61] to decrease the speed down to 1%
[SPD 01]. The percentages will appear in the display
(Items 2, 3 and 4) [Figure 62].
Press button (Item 1) [Figure 61] again to disengage
Speed Management and return to Standard Travel
Speed. [STD] (Item 5) [Figure 62] will appear in the
display.
The system will retain the speed percentage as long as
the loader remains ON.
EXAMPLE: You can be using the machine at 40%
and then disengage Speed Management to
reposition the loader, then re-engage Speed
Management. The speed percentage will still be at
40%.
EXAMPLE: Turning the key OFF or pressing the
STOP button will return the Speed Management
setting to default. The next time you start the
engine and engage Speed Management, the
speed will be at 57% (factory default setting) or
the last default setting saved by the operator. (See
Changing The Factory Default Setting on Page
72.)
NOTE: Two-Speed Loaders Only - You must
disengage Speed Management before you
can select high range.
P-24820C
2
3
1
P-24802C
Left Joystick Right Joystick
P-76461D
P-76461E
P-76461F
P-76461G
2
4
5
3
P-76460B
1