EasyManua.ls Logo

Boiler Company Burnham Hydronics Alpine ALP080 - User Manual

Boiler Company Burnham Hydronics Alpine ALP080
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
101602-01-2/08
Price - $5.00
DNAGNITAREPO,NOITALLATSNI
ROFSNOITCURTSNIECIVRES
ENIPLA
YCNEICIFFEHGIHGNISNEDNOC
TNEVTCERID
RELIOBRETAWTOHDERIF-SAG
As an ENERGY STAR
®
Partner, Burnham Hydronics has determined that the Alpine™ Series meets the ENERGY
STAR
®
guidelines for energy efciency established by the United States Environmental Protection Agency (EPA).
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage,
injury, or loss of life. For assistance or additional information, consult a qualied installer, service agency or the
gas supplier. This boiler requires a special venting system. Read these instructions carefully before installing.

Questions and Answers

  • C
    Christopher StephensonAug 11, 2025
    What to do if my Boiler Company Burnham Hydronics Alpine ALP080 Boiler is not responding to heat call and shows status code 0?
    • N
      Nichole ClarkAug 11, 2025
      If your Boiler Company Boiler isn't responding to a call for heat and the display shows status code '0', it means the boiler isn't detecting the request for heat. Inspect the thermostat or zone wiring for any loose connections, incorrect wiring, or a faulty thermostat/zone control.
  • J
    Jeffery WilliamsAug 19, 2025
    Why does my Boiler Company Burnham Hydronics Alpine ALP080 Boiler display U.125 and the fan is running?
    • S
      Sandra RobertsAug 19, 2025
      If the display reads 'U.125' continuously and the fan is running on your Boiler Company Boiler, the AT250 transformer might be defective. Another possible cause is a blown 'F3' fuse in the MCBA. Replace it with the provided 4A slow-blow fuse.
  • L
    luceromichelleAug 26, 2025
    What to do if the display panel is blank but the fan is running on my Boiler Company Burnham Hydronics Alpine ALP080 Boiler?
    • R
      Richard HansenAug 26, 2025
      If the display panel is blank but the fan is running on your Boiler Company Boiler, a loose 120VAC connection in the wiring between the boiler J-Box and the MCBA could be the cause. Also, check the 'F1' fuse in the MCBA. If it's blown, replace it with the provided 5A fuse.
  • G
    Glenn ButlerSep 3, 2025
    How to troubleshoot a Boiler Company Burnham Hydronics Alpine ALP080 Boiler with a blank display, fan off, and LWCO lights off?
    • C
      Clifford TrevinoSep 3, 2025
      If the display is blank, the fan is off, and the LWCO lights are off on your Boiler Company Boiler, there might be no 120VAC power reaching the boiler. Check the breaker and the wiring between the breaker panel and the boiler.

Summary

IMPORTANT INFORMATION - READ CAREFULLY

Hazard Definitions

Defines DANGER, CAUTION, WARNING, and NOTICE terms for hazard communication.

Flammable Vapor Danger

Specific danger warning about storing or using flammable vapors near appliances.

General Warnings and Notices

II. Pre-Installation

Pre-Installation Safety Warnings

Emphasizes exact adherence to instructions to prevent fire, explosion, damage, or injury.

IV. Venting

Venting Safety Warnings and Guidelines

Details critical warnings about venting system installation and material compatibility.

V. Condensate Disposal

Condensate Trap and Drain Line Procedures

Covers condensate collection, trap function, drain line routing, and disposal warnings.

VI. Water Piping and Trim

Water Piping Safety and Notices

Warns against improper piping and highlights issues like oxygen contamination and water chemistry.

VII. Gas Piping

Gas Piping Safety and Sizing

Covers critical safety warnings and factors for properly sizing gas piping systems.

Gas Piping Pressure Testing and Connections

Details pressure testing procedures, leak detection, and recommended gas piping connections.

VIII. Electrical

Electrical Safety Warnings and General Requirements

Outlines essential safety warnings, grounding, circuit requirements, and control wiring.

Low Voltage Connection Precautions

Warns about potential damage to the control module from incorrect low voltage connections.

IX. Boiler Stacking

X. System Start-up

Pre-Start-up Checks and Procedures

Lists essential checks for venting, piping, electrical, gas, flushing, and leak testing before start-up.

Start-up Sequence and Operating Instructions

Outlines the boiler's start-up sequence and display meanings.

Lighting and Operating Instructions

Provides step-by-step instructions for lighting the boiler and setting the thermostat.

Gas Train Purge and Flame Check

Combustion Testing and Adjustment

Explains how to perform combustion tests and adjust settings for optimal performance.

Supply Water Temperature and Thermostat Adjustment

Field Conversion to LP Gas

Provides instructions and warnings for converting the boiler from natural gas to LP gas.

LP Gas Conversion Procedures and Settings

LP Gas Combustion Settings and Pressure Limits

XI. Operation

Standby Mode Caution

Warns against holding keys in standby mode, which can prevent calls for heat or DHW.

Error Code Display and Interpretation

Field Adjustable Boiler Operating Parameters

Common Field Adjustments and Parameter Details

Adjusting Parameters via Personal Computer

Using Gascom To Monitor The MCBA

III. Component Test Procedures

XII. Service and Maintenance

Service and Maintenance Safety Precautions

Lists critical safety warnings before performing any service or maintenance.

XIII: Troubleshooting

Troubleshooting No Error Code Displayed

Lists common issues without error codes and their potential causes, like power loss or fuse issues.

Troubleshooting Soft Lockout Codes

Explains soft lockout codes, their conditions, and possible causes for system shutdown.

Troubleshooting Hard Lockout Codes

Details hard lockout codes, their conditions, and potential causes, requiring manual reset.

XIV. Repair Parts

Important Product Safety Information

Refractory Ceramic Fiber Product Precautions

Provides safety information regarding refractory ceramic fibers, including protective gear and first aid.

Limited Warranty

Boiler Company Burnham Hydronics Alpine ALP080 Specifications

General IconGeneral
BrandBoiler Company
ModelBurnham Hydronics Alpine ALP080
CategoryBoiler
LanguageEnglish

Related product manuals