TE-55965000-SMM Page 301
CL-604 SUPPLEMENTAL MAINTENANCE MANUAL
EFFECTIVITY:
35-10-05
Revision A Nov 10/2006
THIRD CREW MEMBER OXYGEN SYSTEM - SERVICING
1. INTRODUCTION
A. Purpose
• The following procedure is used to clean and sanitize the face piece.
B. Equipment and Facilities Required
(1) Equipment
• EROS SAN 50 disinfectant swabs
(2) Facilities
•None
2. JOB SET-UP
A. Remove mask from stowage box.
3. PROCEDURE
A. Wipe elastomer face piece quickly and lightly with SAN 50 swab. Allow to completely air dry.
4. JOB COMPLETION
A. Stow face mask in stowage box per EROS Quick Donning Mask-Regulator MF10 Series,
Operating and Maintenance Instructions, document number 4NUT0046A.
B. Remove all equipment used for these tasks and return aircraft to its initial condition.