6
Turn on the CO2 and purge the carbonator vessel by lifting the ring lever of the pressure relief valve on
top of the can, and let gas flow for up to 5 seconds.
Switch on the soda recirc pump (green switch) ensuring that the water supply is on. The rest of the circuit
should now be primed and as much air as possible removed from the circuit. The lifespan of the recirc
pump will be shortened if it is allowed to run dry for prolonged periods.
To achieve optimum carbonation, all air must be purged from the pipework, carbonator can, and the
soda recirc circuit. All air from the circuit will tend to be pumped back to the can, so it is suggested that
this be vented regularly while the circuit is being primed.
Optimum carbonation will only be achieved once the fridge has achieved normal working temperature
and there is ice present in the bath. It is also advisable to initially pull off approx. 1ltr 2litres of
carbonated water per dispense point to allow the carbonated water to circulate round the system.
For the EXL95H/EXL96H Non-Carbonator Deck
Connect the still water in coil to a potable water supply, connect the recirc lines to the bulkhead
connector and the recirc in’ coil.
Connect your supply of soda water to the ‘soda in’ coil.
Power may now be applied to the machine to allow the fridge to form an ice bank.
Installation & Commissioning