Installation Instructions
for the DS835i/DS835iT Series TriTech Microwave/PIR Intrusion Detectors with Pet Immunity
1.0 Description
The DS835i and DS835iT Series are high performance TriTech passive infrared (PIR)/microwave (MW) motion detectors that use advanced signal processing
to provide outstanding catch performance and unsurpassed false alarm immunity. They are designed to detect movement of a human body in the interior of a
structure as it moves across the detector's field of view. When motion is detected, the DS835i and DS835iT send an alarm signal to the control panel. With the
Pet Friendly
pet immunity, these detectors will not detect a dog up to 100 lbs (45 k) or two 60-lb (26 k) dogs, up to 10 cats, numerous rodents, or flying birds.
This pet immunity feature has not been tested by Underwriters Laboratories, Inc. (UL).
3.0 Installation
3.1 Remove the cover using a small
flat-blade screwdriver.
3.2 Press the vertical adjust tab
toward the side of the base and lift out
the board.
3.3 Select a mounting location.
Mount the sensor where an intruder will most
likely cross through the coverage pattern.
Note: The upper areas are not pet
immune.
3.5 Observe the Pet Immunity mounting restrictions.
Pet
Immune
Area
NO
OK
LED ON
7.5-9ft
7.5-9ft
Input Power: 6 VDC to 15 VDC, 16 mA standby (up to 35 mA during
walk testing and alarm). Only use a limited power
source up to 5 A maximum.
Standby Power: No internal standby battery. For UL Certificated
installations, the control unit or a Listed burglary
power supply must provide 4 hrs (64 mAh) standby
power.
Alarm Relay: Silent operating Normally Closed reed relay. Contacts
rated 3 W, 125 mA, 28 VDC maximum for DC resistive
loads; protected by a 4.7 Ω, 1/2 W resistor in the
common “C” leg of the relay. Do not use with capacitive
or inductive loads.
Temperature: Storage and operating temperature range is -40°F to
+120°F (-40°C to +49°C). For UL Certificated
installations, the temperature range is +32°F to +120°F
(0°C to +49°C).
Microwave Frequency:
DS835i/835iT: 10.525 GHz (UL Listed)
DS835iTA: 10.687 GHz (Export only, not UL Listed)
DS835iTB: 9.9 GHz (Export only, not UL Listed)
Coverage: 35 ft by 35 f. (10.7 m by 10.7 m)
Tamper: ("T" models only) Normally Closed (with cover on). Contacts
rated at 28 VDC, 125 mA max. Connect tamper circuit to a
24-hour protection circuit.
Options: B335 Low Profile Swivel Mount Bracket, B338 Ceiling
Mount Bracket. (Using brackets is not recommended for pet
applications and might reduce range and increase dead zone
areas).
Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security Systems,
Inc. Web site at: http://www.boschsecurity.com/datecodes/
Bottom of Detector
Insert screwdriver here or here
Optional anti-tamper
screws at each end
3.4 Avoid:
Don't point where pets can climb.
7.5 - 9 ft.
(2.3 - 2.7 m)
Mount the detector 7.5 - 9 feet
(2.3 - 2.7 meters) above the floor
2.0 Specifications
Moving Objects
Heat
Sources
Windows
and
Uninsulated
Walls
Direct Hot or
Cold
Drafts
Mounting
Outdoors
Direct Sunlight
Air
Conditioning
Outlets
All manuals and user guides at all-guides.com
all-guides.com
Question and Answer IconNeed help?

Do you have a question about the Bosch Security TriTech DS835i Series and is the answer not in the manual?

Summary

Description

Specifications

Input Power

Details power requirements for the detector, including voltage and current limits.

Standby Power

Specifies standby power source requirements for UL Certificated installations.

Alarm Relay

Describes the silent operating reed relay specifications and limitations.

Temperature

Lists storage and operating temperature ranges, including UL specific ranges.

Microwave Frequency

Provides microwave frequency specifications for different detector models.

Coverage

States the detection coverage area dimensions for the device.

Tamper

Details the tamper switch functionality, ratings, and connection requirements.

Options

Lists optional mounting brackets and notes their impact on pet applications.

Installation

Remove Detector Cover

Instructions on how to remove the detector's cover using a small flat-blade screwdriver.

Detach Circuit Board

Steps to detach the circuit board from the detector base by lifting a tab.

Select Mounting Location

Guidance on choosing an optimal mounting position for intruder detection.

Installation Avoidance

Lists environmental factors and locations to avoid during installation.

Pet Immunity Mounting

Critical guidelines for mounting to ensure pet immunity functionality is maintained.

Mount the Detector

Instructions on mounting the detector, including knockout usage and bracket warnings.

Wire the Detector

Instructions for connecting wiring to the detector terminals, including power and alarm contacts.

Snap Board into Base

Procedure to reattach the circuit board to the base by aligning notches.

Select LED Operation

How to configure the detector's LED indicator for ON or OFF states.

Look-Down Mask

Instructions for modifying the mask for look-down detection in non-pet applications.

Microwave Range Adjustment

Guidance on adjusting the microwave detection range and cautions for adjustment.

Walk Test Detector

Procedure for testing detector functionality after installation and annually.

Coverage Patterns

FCC Notice

Bosch Security TriTech DS835i Series Specifications

General IconGeneral
SensitivityAdjustable
Microwave Frequency10.525 GHz
Detection TechnologyMicrowave and PIR
Coverage Area360° coverage
Power Supply9 to 15 VDC
Alarm RelayForm A, normally closed
Tamper Switch/RelayNormally Closed (NC)
Operating Temperature14°F to +120°F (-10°C to +50°C)
Humidity0 to 95% non-condensing