F 016 L70 735 | (11.4.11) Bosch Power Tools
14 | English
Technical Data
Noise/Vibration Information
Declaration of Conformity
Equipment category: 50
Technical file at:
Bosch Lawn and Garden Ltd., PT-LG/EAE,
Stowmarket, Suffolk IP14 1EY, England
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
24.02.2011
Assembly
For Your Safety
f Warning! Switch off, remove plug from
mains before adjusting, cleaning or if ca-
ble is cut, damaged or entangled.
Observe correct mains voltage: The voltage
of the power source must agree with the volt-
age specified on the nameplate of the unit.
Equipment marked with 230 V can also be
connected to 220 V or 240 V.
The circuit must at least be protected as fol-
lows:
AXT22D/25D/23TC/25TC = 13A
An extension cable with a cross section that is
too small causes a distinct reduction in the
performance capabilities of the machine. For
cables to 25 m in length, a cross section of at
least 3x1.5mm
2
is required, for cables more
than 25 m in length, the cross section must be
at least 2.5 mm
2
.
f WARNING! Inadequate extension cables
can be dangerous. Extension cable, plug
and socket must be of watertight con-
struction and intended for outdoor use.
Cable connections should be kept dry and off
the ground.
Quiet-shredder AXT 22 D AXT 25 D AXT 23 TC AXT 25 TC
Article number
3 600 ... H03 0.. H03 1.. H03 2.. H03 3..
Power consumption, S 6
(40/60 s)
1)
W 2200 2500 2300 2500
Power consumption, S 1
W 2000 2300 2100 2300
No-load speed
min
-1
40 40 40 40
Cutting system
Drum Drum Turbine Turbine
Capacity, max.
kg/h 180
2)
190
2)
215
2)
230
2)
Branch diameter, max. mm 38
2)
40
2)
42
2)
45
2)
Collection box l5353 53 53
Weight according to
EPTA-Procedure 01/2003
kg 31.3 31.3 30.5 30.5
Protection class
/I /I /I /I
1)
The S 6 operating mode (40 %) indicates a load profile of 40 s load and 60 s idle time. For practical applica-
tion, continuous operation is permitted.
2)
Depending on the hardness of the wood.
Starting cycles generate brief voltage drops. Interference with other equipment/machines may occur in case of
unfavourable mains system conditions. Malfunctions are not to be expected for system impedances below
0.36 ohm.
Measured sound values determined according to 2000/14/EC
(1.60 m height, 1 m distance away).
3 600 ... H03 0..
H03 1..
H03 2..
H03 3..
Typically the A-weighted noise levels of the product are:
Sound pressure level
Sound power level
Uncertainty K
Wear hearing protection!
dB(A)
dB(A)
dB
81
89
=3
82
90
=2
3 600 ... H03 0..
H03 1..
H03 2..
H03 3..
We declare under our sole responsibility that the product de-
scribed under “Technical data” is in conformity with the following
standards or standardization documents: EN 60335, EN 13683 ac-
cording to the provisions of the directives 2004/108/EC,
2006/42/EC, 2000/14/EC.
2000/14/EC: Guaranteed sound power level
Conformity assessment procedure according to Annex V.
dB(A) 92 92
Dr. Egbert Schneider
Senior Vice President
Engineering
Dr. Eckerhard Strötgen
Head of Product
Certification