Key Symbols and Safety Instructions

Key to Symbols

Defines symbols used for warnings and important information within the manual.

Safety Precautions Overview

Provides crucial safety warnings, precautions, and guidelines for furnace operation and maintenance.

Troubleshooting Procedures

Electrostatic Discharge (ESD) Precautions

Details precautions to prevent damage to electronic components from static discharge.

Resetting Furnace From Lockout

Explains methods for resetting the furnace after it enters a lockout state.

Error Flash Code Diagnostics

No Flash and No Fan (System Start Failure)

Troubleshooting steps for when the system does not start and no LED flashes are observed.

7 & 8 Flashes (Ignition or Flame Dropout Lockout)

Addresses issues causing system lock-out due to failed ignition or too many flame dropouts.

2 Flashes (Low Fire Pressure Switch Stuck Closed)

Troubleshooting guide for a system error indicated by 2 LED flashes.

3, 6, & 13 Flashes (Pressure Switch Malfunctions)

Covers troubleshooting for 3, 6, and 13 flash error codes related to pressure switches.

4, 5, & 11 Flashes (Limit/Rollout Switch Errors)

Details troubleshooting for errors indicated by 4, 5, and 11 flashes related to limit/rollout switches.

9 Flashes (Incorrect L1/L2 Polarity)

Steps to troubleshoot incorrect polarity of L1/L2 indicated by 9 flashes.

Rapid Flashes (Low Flame Condition)

Troubleshooting guide for rapid flash error codes indicating a low flame condition.

Appendix A: Sequence of Operation

Two Stage Controller Logic Overview

Explains the logic for two heating modes and single-stage thermostat operation.

Low Fire Heating Mode Logic (W1 Signal)

Details the sequence of operation for low fire heating mode with a W1 signal.

High Fire Heating Mode Logic (W1+W2 Signal)

Details the sequence of operation for high fire heating mode with W1+W2 signals.

Ignition Failure and Reignition Sequence

Describes the logic for ignition failure and the subsequent re-ignition attempts.